• surge protection device Timelec SPD type2 20kA 1.5kV 18mm surge arrester diverter
  • surge protection device Timelec SPD type2 20kA 1.5kV 18mm surge arrester diverter
  • surge protection device Timelec SPD type2 20kA 1.5kV 18mm surge arrester diverter
  • surge protection device Timelec SPD type2 20kA 1.5kV 18mm surge arrester diverter

surge protection device Timelec SPD type2 20kA 1.5kV 18mm surge arrester diverter

Size: Small
Operation Voltage: Low Voltage
Shape: Cuboid
Samples:
US$ 8/Piece 1 Piece(Min.Order)
| Order Sample
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
surge protection device Timelec SPD type2 20kA 1.5kV 18mm surge arrester diverter pictures & photos
surge protection device Timelec SPD type2 20kA 1.5kV 18mm surge arrester diverter
US $6-8 / Piece
Min. Order: 60 Pieces
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2015

Suppliers with verified business licenses

Secured Trading Service
Zhejiang, China
Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
Experienced Team
The supplier has 6 foreign trading staff(s) and 3 staff(s) with over 6 years of overseas trading experience
to see all verified strength labels (22)
  • Overview
  • Product Description
  • Product Parameters
  • Installation Instructions
Overview

Basic Info.

Model NO.
TMSPD
Material
PBT Fireproof
Certification
CE
Brand
Timelec
Uc
275V / 255V
In
20kA
Imax
40kA
Up
1.5kV
IEC
IEC61643-11
IP
IP20
Protection
Class II, T2
Transport Package
Carton Box
Specification
18mm
Trademark
Timelec, OEM / Private Label brands
Origin
China
HS Code
853620
Production Capacity
1000000

Packaging & Delivery

Package Size
10.00cm * 4.00cm * 7.80cm
Package Gross Weight
0.150kg

Product Description

Product Description

Surge Protective Devices are designed to protect against transient surge conditions. Large single surge events, such as lightning, can reach hundreds of thousands of volts and can cause immediate or intermittent equipment failure. However, lightning and utility power anomalies only account for 20% of transient surges. The remaining 80% of surge activity is produced internally. Although these surges may be smaller in magnitude, they occur more frequently and with continuous exposure can degrade sensitive electronic equipment within the facility.

surge protection device Timelec SPD type2 20kA 1.5kV 18mm surge arrester divertersurge protection device Timelec SPD type2 20kA 1.5kV 18mm surge arrester diverter

A power surge is a brief overvoltage event that can damage electrical devices and is a common cause for the failure of electrical equipment. Surges can damage and reduce the lifespan of:

  • Heating and Air Conditioning Systems
  • Washers and Dryers
  • Water Heaters
  • Ranges & Refrigerators
  • Lighting
  • Entertainment Systems

According to the National Electrical Manufacturers Association, the average home has $15,000 worth of equipment that can be damaged by surges.

Common Causes of Surge:
It is estimated that 80% of surges are caused by internal sources

Internal Sources:

  • Large appliances turning on / off
  • Faulty wiring or loose connections
  • Overloaded circuits, short circuits, or ground faults
  • Power recovery

External Sources:

  • Lightning
  • Damage to power lines
  • Utility power grid switching


NEW 2020 National Electrical Code Requirements
All new and renovated homes are required to be protected by Listed and Approved Type 1 or Type 2 Surge Protective Devices.

Type 1:
Permanently connected Surge Protective Device.  Protects against external and internal surges. May be installed inside or outside the home.

Type 2:
Permanently connected Surge Protective Device installed in, or next to, breaker box. Protects again internal or external surges.

Type 3:
Extra protection. Point-of-use Surge Protective Device. Must be used in conjunction with Type 1 or Type 2 SPD to meet 2020 code requirements.

Use Type 1, 2, and 3 SPDs for the best level of protection.  
 

Product Parameters
Product category Surge protection
Product type SURGE PROTECTIVE DEVICE
Product model HLSPD,SPD,TMSPD2
Unique selling proposition ·TMSPD1 SPD are suit for IT,TT,TN-C,TN-S,TN-C-S and low-voltage AC power distribution system, protect both direct and indirect lighting impulse and other transient over voltage.
·TMSPD1 surge protection device have high energy MOV chip, fast response speed.
·Products comply with IEC61643-1.2005, IEC61643-11.2011 standard.
Technical data Type of SPD according to EN 61643-11 Type 2
SPD according to IEC 61643-1 Class II
Nominal a.c voltage( Un) 230V
Max continuous operating a.c voltage (Uc) 275/320/385/440V
Nominal discharge current (In 8/20|jS) 10/20KA
Max. discharge current (Imax 8/20pS) 20/40KA
Voltage protection level (Up) <1.3/1.4/1.5/1.8/2.2KV
Response time (tA) <25ns
Operating temperature range (Tu) -40°C +80°C
Operating state/fault indication Green/red
Cross-section area (min) 4mm²
Cross-section area (Max) 16mm²
For mounting on 35mm DIN rail acc to EN60715
Degree of protection IP20
Terminal screw torque 2.5N·m
Approvals TUV
 
Installation Instructions

Selection of SPD:
For a power distribution system, the main characteristics used to define the lightning protection system and select a SPD to protect an electrical installation in a building are:

  • SPD
    • quantity of SPD
    • type
    • level of exposure to define the SPD's maximum discharge current Imax.
  • Short circuit protection device
    • maximum discharge current Imax;
    • short-circuit current Isc at the point of installation.
surge protection device Timelec SPD type2 20kA 1.5kV 18mm surge arrester diverter

The other characteristics for selection of a SPD are predefined for an electrical installation.

  • number of poles in SPD;
  • voltage protection level Up;
  • operating voltage Uc.

This sub-section Design of the electrical installation protection system describes in greater detail the criteria for selection of the protection system according to the characteristics of the installation, the equipment to be protected and the environment.

Location and types of SPD:
surge protection device Timelec SPD type2 20kA 1.5kV 18mm surge arrester diverter

Connection of SPD:
Connections of a SPD to the loads should be as short as possible in order to reduce the value of the voltage protection level (installed Up) on the terminals of the protected equipment.

The total length of SPD connections to the network and the earth terminal block should not exceed 50 cm.

surge protection device Timelec SPD type2 20kA 1.5kV 18mm surge arrester diverter
surge protection device Timelec SPD type2 20kA 1.5kV 18mm surge arrester diverter

                                    SPD in plastic enclosure                                                                             SPD in metal enclosure
 

surge protection device Timelec SPD type2 20kA 1.5kV 18mm surge arrester diverter
surge protection device Timelec SPD type2 20kA 1.5kV 18mm surge arrester diverter

 

RED: Replace
Once the indicator shows RED, the product must be replaced.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
surge protection device Timelec SPD type2 20kA 1.5kV 18mm surge arrester diverter pictures & photos
surge protection device Timelec SPD type2 20kA 1.5kV 18mm surge arrester diverter
US $6-8 / Piece
Min. Order: 60 Pieces
Diamond Member Since 2015

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory & Trading Company
Number of Employees
285
Year of Establishment
2014-09-18