Product Details
Customization: Available
Breaking Capacity: Low Voltage Circuit Breakers
Operation: Electric Type
Still deciding? Get samples of $ !
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company

360° Virtual Tour

Industry-leading Audited Factory

Secured Trading Service
Diamond Member Since 2015

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
to see all verified strength labels (22)
  • TMRO7-40 40A RC-Unit+MCB 2P 6kA RCBO IEC 61009-1 RCBO
  • TMRO7-40 40A RC-Unit+MCB 2P 6kA RCBO IEC 61009-1 RCBO
  • TMRO7-40 40A RC-Unit+MCB 2P 6kA RCBO IEC 61009-1 RCBO
  • TMRO7-40 40A RC-Unit+MCB 2P 6kA RCBO IEC 61009-1 RCBO
  • TMRO7-40 40A RC-Unit+MCB 2P 6kA RCBO IEC 61009-1 RCBO
  • TMRO7-40 40A RC-Unit+MCB 2P 6kA RCBO IEC 61009-1 RCBO
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Our Advantages
  • FAQ
  • Certifications
  • Packaging & Shipping
  • Installation Instructions
  • Company Profile
Overview

Basic Info.

Model NO.
TMRO7-40 10kA 1P+N C40 30mA Type Ac Electronic
Speed
High-Speed Circuit Breaker
Arc-extinguishing Medium
Air
Installation
Fixed
Structure
RCBO
Poles Number
2
Type
Circuit Breaker
Function
Overcurrent Protection, OVP(Overvoltage Protection), RCCB, short circuit
Certification
ISO9001-2000, CE, CB, UKCA, NF, TIS
Standard
IEC 61009-1
Pole
1P+N
Tripping curve
C
Rated Current (in)
40a
Residual Current (LΔn)
30mA
Icn
10kA
Electrical Life
20, 000
Mechenical Life
20, 000
keywords
circuit breaker
keywords2
RCBO
keywords3
GFCI
Transport Package
White Gift Box, Yellow Carton Box
Specification
90 X 73 X 36 mm
Trademark
Timelec, OEM / Private Label brands
Origin
China
HS Code
8536200000
Production Capacity
1, 200, 000

Packaging & Delivery

Package Size
9.00cm * 8.00cm * 4.50cm
Package Gross Weight
0.350kg

Product Description

Product Description

The RCBO, or Residual-current Circuit Breaker with Overcurrent protection, commonly referred to as GFCI (Ground Fault Circuit Interrupter), is meticulously designed to adhere to the stringent standards of IEC/BS EN 61009-1 and GB16917. This sophisticated circuit breaker seamlessly integrates the advanced capabilities of both an MCB and RCD (RCCB), ensuring unrivaled protection. Timelec's RCBO is engineered to safeguard against overloads, short-circuits, and residual currents, providing peace of mind. Its tripping mechanism is ingeniously crafted in two distinct forms, namely ELE (Electronic) and ELM (ElectroMagnetic). Furthermore, it is available in four primary types based on the waveform and frequency of fault current: Type Ac, Type A, Type F, and Type B. These selections are stringently mandated by national standards across diverse countries, ensuring optimal safety and reliability.
 

Product Parameters
Product category CIRCUIT BREAKER
Product type Residual current operated circuit-breakers with integral overcurrent protection (RCBO)
Product model TMRO7-40
Technical data   Standard IEC 61009-1, GB16917.1
Electrical features Rated curret (In) 6A, 10A, 16A, 20A,25A, 32A, 40A
Trip curve B, C, D
Model Electronic
RCD Type AC, A
Pole 1P + N
Rate voltage (Ue) 240V
Insulation voltage(Ui) 500V
Rated frequency 50/60Hz
Energy limiting class 3
Rated residual operating current (IΔn) 30mA, 100mA, 300mA
Rated breaking capacity (Icn) 6KA/10KA
Rated operating short circuit breaking capacity (Ics) 6KA/7.5KA
Rated residual making and breaking capacity(IΔm) 3000A
Rated impulse withstand voltage (Uimp) 4KV
Surge current resistance / at (8/20) μs 3KA
Electrical life 4,000
Pollution degree 2
Mechanical features Mechanical life 10,000
Protection degree IP20
Ambient temperature (with daily averages35°C) -25°C +40°C
Storage temperature -25°C +70°C
Installation Terminal connection type Cable, busbar
Connection capacity (input) 25mm2
Connection capacity (output) 25mm2
Tightening torque (input) 2.5Nm
Tightening torque (output) 2.5Nm
35mm DIN rail
Our Advantages

TMRO7-40 40A RC-Unit+MCB 2P 6kA RCBO IEC 61009-1 RCBO
TMRO7-40 40A RC-Unit+MCB 2P 6kA RCBO IEC 61009-1 RCBO

FAQ
RCBO = MCB + RCD;
Warranting reliability and safety for people and assets;
2 tripping mechanisms: delayed thermal tripping: overload protection;
magnetic tripping: short circuit protection.
Type of leakage current:
Type Ac, A (I), F, B;
Installation: DIN rail 35mm by fast clip;
Choose by: a) protection Type Ac, A (I), F, B; b) leakage current 30mA,100mA,300mA, c) overcurrent curve; d) rate current; e) breaking capacity.
Certifications
TMRO7-40 40A RC-Unit+MCB 2P 6kA RCBO IEC 61009-1 RCBO
TMRO7-40 40A RC-Unit+MCB 2P 6kA RCBO IEC 61009-1 RCBO
TMRO7-40 40A RC-Unit+MCB 2P 6kA RCBO IEC 61009-1 RCBO

 

Packaging & Shipping

Presented in a pristine white gift box with a single unit per box,

TMRO7-40 40A RC-Unit+MCB 2P 6kA RCBO IEC 61009-1 RCBO
TMRO7-40 40A RC-Unit+MCB 2P 6kA RCBO IEC 61009-1 RCBO
TMRO7-40 40A RC-Unit+MCB 2P 6kA RCBO IEC 61009-1 RCBO


and further packaged in a vibrant yellow carton box containing 60 units per carton. This ensures maximum protection during transit.

TMRO7-40 40A RC-Unit+MCB 2P 6kA RCBO IEC 61009-1 RCBO
As a pivotal component in the distribution network,
Timelec provides a robust corrugated carton box featuring:

Exceptional quality, ensuring product safety,
High edge crush resistance to withstand external forces,
and a neutral, yet elegant, black print for a sophisticated appearance.

 

Installation Instructions

TMRO7-40 40A RC-Unit+MCB 2P 6kA RCBO IEC 61009-1 RCBO

Company Profile

TMRO7-40 40A RC-Unit+MCB 2P 6kA RCBO IEC 61009-1 RCBOTMRO7-40 40A RC-Unit+MCB 2P 6kA RCBO IEC 61009-1 RCBO

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier