[manufacture] 230V Surge Suppressor, 20kA In, 40kA Imax Capacity

Product Details
Customization: Available
Type: Power Source Arrester
Structure: Valve Type Arrester
Still deciding? Get samples of $ !
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company

360° Virtual Tour

Industry-leading Audited Factory

Secured Trading Service
Diamond Member Since 2015

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
to see all verified strength labels (22)
  • [manufacture] 230V Surge Suppressor, 20kA In, 40kA Imax Capacity
  • [manufacture] 230V Surge Suppressor, 20kA In, 40kA Imax Capacity
  • [manufacture] 230V Surge Suppressor, 20kA In, 40kA Imax Capacity
  • [manufacture] 230V Surge Suppressor, 20kA In, 40kA Imax Capacity
  • [manufacture] 230V Surge Suppressor, 20kA In, 40kA Imax Capacity
  • [manufacture] 230V Surge Suppressor, 20kA In, 40kA Imax Capacity
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Installation Instructions
Overview

Basic Info.

Model NO.
TMSPD1
Installation
Parallel Arrester
Application
AC/DC System
Size
Small
Operation Voltage
Low Voltage
Shape
Cuboid
Material
ZnO
Certification
ISO9001
Brand
Timelec
Uc
230V
In
20kA
Imax
40kA
Up
1.5kV
IEC
IEC61643-11
IP
IP20
Protection
Class II, T2
Transport Package
Carton Box
Specification
36*69*91mm
Trademark
Timelec, OEM / Private Label brands
Origin
China
HS Code
853620
Production Capacity
1000000

Packaging & Delivery

Package Size
4.00cm * 9.30cm * 7.50cm
Package Gross Weight
0.300kg

Product Description

Product Description

Our Surge Protective Devices are meticulously engineered to provide superior protection for your electrical systems against transient surge conditions. These devices stand as a formidable barrier against significant surge events, such as lightning strikes that can unleash voltages in the hundreds of thousands. Such events pose threats of immediate or sporadic equipment failures. Interestingly, while lightning and utility power irregularities account for only 20% of transient surges, a remarkable 80% of these surges are internally generated within facilities. Although internal surges tend to be of lower magnitude, their frequent occurrence and persistent exposure can silently compromise the performance and durability of your delicate electronic equipment.

Product Features
1. Versatile 1P+N phase protection adaptable for both AC and DC systems, ensuring a broad spectrum of safety.

2. User-friendly pluggable module design allows for seamless installation and effortless maintenance.

3. Unmatched high discharge capacity paired with swift response time offers exceptional surge protection.

4. Outfitted with dual thermal disconnection devices, delivering enhanced and dependable protection.

5. Groundbreaking green window indicator that switches upon fault detection, complete with remote alarm control for proactive oversight.


A power surge signifies a brief overvoltage occurrence that endangers electrical devices, often culminating in equipment malfunctions and diminished lifespan. Surges are infamous for their capacity to damage and reduce the longevity of numerous household systems and appliances, including:

  • Heating and Air Conditioning Systems
  • Washers and Dryers
  • Water Heaters
  • Ranges & Refrigerators
  • Lighting
  • Entertainment Systems

Did you know that according to the National Electrical Manufacturers Association, the average home contains approximately $15,000 worth of equipment vulnerable to surge damage?

Common Causes of Surges:
Expert analysis reveals that a substantial 80% of surges originate from internal sources within the premises.

Internal Sources:

  • Sudden surges frequently occur when large appliances are powered on or off.
  • Faulty wiring or loose connections can also incite surge events.
  • Overloaded circuits, short circuits, or ground faults are prevalent internal surge triggers.
  • Power recovery incidents are additional contributors to surges.

External Sources:

  • Lightning strikes serve as a quintessential example of external surge sources.
  • Physical damage to power lines can precipitate surge events.
  • Utility power grid switching is another potential external surge source.


NEW 2020 National Electrical Code Requirements
The latest 2020 code mandates that all new and renovated homes must be equipped with Listed and Approved Type 1 or Type 2 Surge Protective Devices, ensuring peak safety and compliance.

Type 1:
A permanently connected Surge Protective Device, Type 1 offers comprehensive protection against both external and internal surges. It can be installed either within or outside the home.

Type 2:
This permanently connected Surge Protective Device is installed in, or adjacent to, the breaker box, offering robust defense against internal or external surges.

Type 3:
For additional safeguarding, the Type 3 is a point-of-use Surge Protective Device. It must be used in tandem with Type 1 or Type 2 SPDs to comply with the 2020 code requirements, providing optimal protection.

d2c9fdb9

Product Parameters
Product category Surge protection
Product type SURGE PROTECTIVE DEVICE
Product model HLSPD,SPD,TMSPD2
Unique selling proposition ·TMSPD1 SPD are suit for IT,TT,TN-C,TN-S,TN-C-S and low-voltage AC power distribution system, protect both direct and indirect lighting impulse and other transient over voltage.
·TMSPD1 surge protection device have high energy MOV chip, fast response speed.
·Products comply with IEC61643-1.2005, IEC61643-11.2011 standard.
Technical data Type of SPD according to EN 61643-11 Type 2
SPD according to IEC 61643-1 Class II
Nominal a.c voltage( Un) 230V
Max continuous operating a.c voltage (Uc) 275/320/385/440V
Nominal discharge current (In 8/20|jS) 10/20KA
Max. discharge current (Imax 8/20pS) 20/40KA
Voltage protection level (Up) <1.3/1.4/1.5/1.8/2.2KV
Response time (tA) <25ns
Operating temperature range (Tu) -40°C +80°C
Operating state/fault indication Green/red
Cross-section area (min) 4mm²
Cross-section area (Max) 16mm²
For mounting on 35mm DIN rail acc to EN60715
Degree of protection IP20
Terminal screw torque 2.5N·m
Approvals TUV
 
Installation Instructions

Selection of SPD:
To craft an unparalleled power distribution system, focus on the key characteristics vital for designing an effective lightning protection scheme. By selecting the ideal Surge Protective Device (SPD), you can ensure your building's electrical installation is impeccably shielded against potential lightning threats. The following attributes are indispensable:

  • SPD
    • Quantity of SPD
    • Type
    • Understanding the level of exposure is pivotal in determining the maximum discharge current, Imax, of your SPD. This ensures robust safety and reliability.
  • Short Circuit Protection Device
    • Maximum discharge current, Imax;
    • Short-circuit current, Isc at the installation point.
[manufacture] 230V Surge Suppressor, 20kA In, 40kA Imax Capacity

Predetermined additional characteristics are essential for the selection of an SPD, facilitating its seamless integration into the electrical installation, thereby maximizing effectiveness.

  • Number of poles in SPD;
  • Voltage protection level, Up;
  • Operating voltage, Uc.

This Sub-sectionDesign of the Electrical Installation Protection SystemThis comprehensive segment meticulously explores the criteria necessary for selecting the ideal protection system. It considers the unique characteristics of the installation, the equipment requiring safeguarding, and the environmental conditions.

Location and Types of SPD:
[manufacture] 230V Surge Suppressor, 20kA In, 40kA Imax Capacity

Connection of SPD:
It is crucial to ensure that SPD connections to the loads are minimized in length. This strategy effectively reduces the voltage protection level (installed Up) at the terminals of the safeguarded devices, optimizing their protection.

Maintain the aggregate length of SPD connections to both the network and the earth terminal block at a maximum of 50 cm. This is vital to ensure optimal performance and protection.

[manufacture] 230V Surge Suppressor, 20kA In, 40kA Imax Capacity
[manufacture] 230V Surge Suppressor, 20kA In, 40kA Imax Capacity

Options: SPD in a plastic enclosure; SPD in a metal enclosure

[manufacture] 230V Surge Suppressor, 20kA In, 40kA Imax Capacity
[manufacture] 230V Surge Suppressor, 20kA In, 40kA Imax Capacity

 

RED: Replace
If the indicator turns RED, it is imperative to replace the product immediately to ensure ongoing optimal protection and system reliability.

Send your message to this supplier