Our Surge Protective Devices are meticulously engineered to provide superior protection for your electrical systems against transient surge conditions. These devices stand as a formidable barrier against significant surge events, such as lightning strikes that can unleash voltages in the hundreds of thousands. Such events pose threats of immediate or sporadic equipment failures. Interestingly, while lightning and utility power irregularities account for only 20% of transient surges, a remarkable 80% of these surges are internally generated within facilities. Although internal surges tend to be of lower magnitude, their frequent occurrence and persistent exposure can silently compromise the performance and durability of your delicate electronic equipment.
Product Features
1. Versatile 1P+N phase protection adaptable for both AC and DC systems, ensuring a broad spectrum of safety.
2. User-friendly pluggable module design allows for seamless installation and effortless maintenance.
3. Unmatched high discharge capacity paired with swift response time offers exceptional surge protection.
4. Outfitted with dual thermal disconnection devices, delivering enhanced and dependable protection.
5. Groundbreaking green window indicator that switches upon fault detection, complete with remote alarm control for proactive oversight.
A power surge signifies a brief overvoltage occurrence that endangers electrical devices, often culminating in equipment malfunctions and diminished lifespan. Surges are infamous for their capacity to damage and reduce the longevity of numerous household systems and appliances, including:
Did you know that according to the National Electrical Manufacturers Association, the average home contains approximately $15,000 worth of equipment vulnerable to surge damage?
Common Causes of Surges:
Expert analysis reveals that a substantial 80% of surges originate from internal sources within the premises.
Internal Sources:
External Sources:
NEW 2020 National Electrical Code Requirements
The latest 2020 code mandates that all new and renovated homes must be equipped with Listed and Approved Type 1 or Type 2 Surge Protective Devices, ensuring peak safety and compliance.
Type 1:
A permanently connected Surge Protective Device, Type 1 offers comprehensive protection against both external and internal surges. It can be installed either within or outside the home.
Type 2:
This permanently connected Surge Protective Device is installed in, or adjacent to, the breaker box, offering robust defense against internal or external surges.
Type 3:
For additional safeguarding, the Type 3 is a point-of-use Surge Protective Device. It must be used in tandem with Type 1 or Type 2 SPDs to comply with the 2020 code requirements, providing optimal protection.
d2c9fdb9
Product category | Surge protection | |
Product type | SURGE PROTECTIVE DEVICE | |
Product model | HLSPD,SPD,TMSPD2 | |
Unique selling proposition | ·TMSPD1 SPD are suit for IT,TT,TN-C,TN-S,TN-C-S and low-voltage AC power distribution system, protect both direct and indirect lighting impulse and other transient over voltage. ·TMSPD1 surge protection device have high energy MOV chip, fast response speed. ·Products comply with IEC61643-1.2005, IEC61643-11.2011 standard. |
|
Technical data | Type of SPD according to EN 61643-11 | Type 2 |
SPD according to IEC 61643-1 | Class II | |
Nominal a.c voltage( Un) | 230V | |
Max continuous operating a.c voltage (Uc) | 275/320/385/440V | |
Nominal discharge current (In 8/20|jS) | 10/20KA | |
Max. discharge current (Imax 8/20pS) | 20/40KA | |
Voltage protection level (Up) | <1.3/1.4/1.5/1.8/2.2KV | |
Response time (tA) | <25ns | |
Operating temperature range (Tu) | -40°C +80°C | |
Operating state/fault indication | Green/red | |
Cross-section area (min) | 4mm² | |
Cross-section area (Max) | 16mm² | |
For mounting on | 35mm DIN rail acc to EN60715 | |
Degree of protection | IP20 | |
Terminal screw torque | 2.5N·m | |
Approvals | TUV |
Selection of SPD:
To craft an unparalleled power distribution system, focus on the key characteristics vital for designing an effective lightning protection scheme. By selecting the ideal Surge Protective Device (SPD), you can ensure your building's electrical installation is impeccably shielded against potential lightning threats. The following attributes are indispensable:
Predetermined additional characteristics are essential for the selection of an SPD, facilitating its seamless integration into the electrical installation, thereby maximizing effectiveness.
This Sub-sectionDesign of the Electrical Installation Protection SystemThis comprehensive segment meticulously explores the criteria necessary for selecting the ideal protection system. It considers the unique characteristics of the installation, the equipment requiring safeguarding, and the environmental conditions.
Location and Types of SPD:
Connection of SPD:
It is crucial to ensure that SPD connections to the loads are minimized in length. This strategy effectively reduces the voltage protection level (installed Up) at the terminals of the safeguarded devices, optimizing their protection.
Maintain the aggregate length of SPD connections to both the network and the earth terminal block at a maximum of 50 cm. This is vital to ensure optimal performance and protection.
Options: SPD in a plastic enclosure; SPD in a metal enclosure