Afdd TMA3-40 1P+N Circuit Breaker with B/C/D Tripping Curve

Product Details
Customization: Available
Breaking Capacity: Low Voltage Circuit Breakers
Operation: Electric Type
Still deciding? Get samples of $ !
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW PayPal
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company

360° Virtual Tour

Industry-leading Audited Factory

Secured Trading Service
Diamond Member Since 2015

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
to see all verified strength labels (22)
  • Afdd TMA3-40 1P+N Circuit Breaker with B/C/D Tripping Curve
  • Afdd TMA3-40 1P+N Circuit Breaker with B/C/D Tripping Curve
  • Afdd TMA3-40 1P+N Circuit Breaker with B/C/D Tripping Curve
  • Afdd TMA3-40 1P+N Circuit Breaker with B/C/D Tripping Curve
  • Afdd TMA3-40 1P+N Circuit Breaker with B/C/D Tripping Curve
  • Afdd TMA3-40 1P+N Circuit Breaker with B/C/D Tripping Curve
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • FAQ
  • Our Advantages
  • Certifications
  • Packaging & Shipping
  • Installation Instructions
  • Company Profile
Overview

Basic Info.

Model NO.
TMA1-40 1P+N 6kA C40 TypeAC
Speed
High-Speed Circuit Breaker
Arc-extinguishing Medium
Air
Installation
Fixed
Structure
AFDD
Poles Number
1P+N
Type
Circuit Breaker
Function
Overcurrent Protection, RCCB
Certification
VDE, ISO9001-2000, CE, CB, Ukca, NF
Standard
IEC/En 62606 & IEC 61009-1
Pole
1P+N
Tripping Curve
B, C, D
Rated Current (in)
6A, 10A, 16A, 20A, 25A, 32A, 40A
Residual Current Type
Type A, AC
Residual Current (LΔn)
30mA, 100mA, 300mA
Making Breaking Capacity (IΔm)
2, 000A
Icn
6kA
Energy Limiting Class
3
keywords
afdd and rcd
keywords2
afdd circuit breaker
keywords3
arc detection device
Transport Package
White Gift Box, Yellow Carton Box
Specification
115 x 69.6 x 18 mm
Trademark
Timelec, OEM / Private Label brands
Origin
China
HS Code
8536200000
Production Capacity
200, 000

Packaging & Delivery

Package Size
9.00cm * 3.30cm * 1.20cm
Package Gross Weight
0.200kg

Product Description

Product Description

Introducing the AFDD, also revered as the Arc-Fault Detection Device or AFCI in North America. This marvel of engineering meets the stringent IEC/BS EN 62606 standards, ensuring unparalleled safety and reliability. With this device, you can rest easy, knowing your electrical systems are protected by the best.
Timelec is a beacon of excellence in the world of circuit protection, offering a comprehensive range of devices that set industry benchmarks. Our MCBs excel in providing robust short-circuit and overload protection, while our RCDs (RCCB) serve as stalwarts of residual current defense. However, the threat of electrical fires looms large, with arcs being the culprits in 90% of such incidents. The AFDD is your indispensable sentinel, offering vital arc protection to preserve both lives and properties with unmatched prowess.

 

The innovative Timelec AFDD is a trailblazing hybrid device that seamlessly integrates AFDD and RCBO features. It offers comprehensive protection against a spectrum of threats-short-circuit, overload, residual current, arcs, and over-voltage-all while complying with rigorous IEC/BS EN 62606 and IEC/BS EN 61009-1 standards. This intelligent device can distinguish between benign and dangerous arcs, promptly disconnecting the circuit when detecting arcs typically caused by loose connections, a common precursor to dangerous fires, particularly in older homes.

Product Parameters
Product category CIRCUIT BREAKER
Product type ARC FAULT DETECTION DEVICES (AFDDs)
Product model TMA3-40
Unique selling
proposition
With AFD+RCBO protection
With Over-vol. protection
Total length, 115mm
Technical data   Standard IEC/EN 62606 & IEC 61009-1
Electrical features Rated curret (In) 6A,10A,16A,20A,25A,32A,40A
Trip curve B, C, D
Model Electronic
RCD Type AC, A
Pole 1P+N
Rate voltage (Ue) 240V
Insulation voltage(Ui) 500V
Rated frequency 50Hz
Energy limiting class 3
Rated residual operating current (IΔn) 30mA, 100mA, 300mA
Rated breaking capacity (Icn) 6KA
Rated operating short circuit breaking capacity (Ics) 6KA
Rated residual making and breaking capacity(IΔm) 2000A
Rated impulse withstand voltage (Uimp) 4KV
Surge current resistance / at (8/20) μs 3KA
Overvoltage protection 270V-300V
Electrical life 4,000
Pollution degree 2
Mechanical features Mechanical life 20,000
Protection degree IP20
Ambient temperature (with daily averages35°C) -25°C +40°C
Storage temperature -25°C +70°C
Installation Terminal connection type Cable, busbar
Connection capacity (input) 25mm2
Connection capacity (output) 16mm2
Tightening torque (input) 2.5Nm
Tightening torque (output) 1.2Nm
35mm DIN rail
Afdd TMA3-40 1P+N Circuit Breaker with B/C/D Tripping Curve
FAQ
Whatarearcs?
Visible plasma discharges caused by electrical current passing through a normally nonconductive medium, such as air.
It is caused when the electrical current ionizes gases in the air.
The temperature can exceed 600 ºC, sufficient to start a fire.
(20% fire associated with electrical distribution or other electrical appliance faults.)
Afdd TMA3-40 1P+N Circuit Breaker with B/C/D Tripping Curve
Whatcauses arcs?
An arc is created when the electrical current jumps between two conductive material. Most 2 types of arcs are Serial
Arc and Parallel Arc.

Most common causes includes:
1. worn contacts in electrical equipment,
2. damage to insulation,
3. break in cable and loose connections, Etc.
Afdd TMA3-40 1P+N Circuit Breaker with B/C/D Tripping Curve


What is AFDD?
AFDD is protective device installed in consumer units to provide protection from arc faults.
It uses microprocessor technology to analyze the waveform of the electricity being used to detect any unusual signatures
which would signify an arc on the circuit.

It will cut off the power to the affected circuit and could prevent a fire.
Afdd TMA3-40 1P+N Circuit Breaker with B/C/D Tripping Curve
Do I need to install AFDD?
Yes, it is highly recommended where there is an increased risk of fire
Afdd TMA3-40 1P+N Circuit Breaker with B/C/D Tripping CurveAfdd TMA3-40 1P+N Circuit Breaker with B/C/D Tripping Curve
According to IEC 60364 - Electrical installations of buildings Part 4-42 :
Arc Fault Detection Devices are designed to limit fire risks caused by the presence of arc fault currents in the final circuits of a fixed installation.They are installed in electrical switchboards, to protect circuits supplying power sockets and lighting and are especially recommended in cases of renovation.


More specifically, the installation of the AFDD is highly recommended to protect circuits with highest risk of fire, such as:
Protruding cables (risk of knocks)
Outside cables (greater risk of deterioration)
Unprotected cables in secluded areas (like storage rooms)
Aging, deteriorating wiring or wiring for which the connection boxes are inaccessible.
Our Advantages

The Timelec AFDD (AFCI) boasts a cleverly compact design, measuring a mere 115mm in length.
Despite its small size, it delivers steadfast protection and optimal performance, ensuring safety without any compromise.

For comprehensive protection in both residential and commercial spaces, Timelec AFDD is the premier choice, providing unparalleled peace of mind.

Timelec enriches your experience with a plethora of customization options:

Sophisticated laser or pad printing options for precise and elegant branding.
High-value presentation in select white gift boxes, enhancing the perceived worth of our products.
Robust yellow carton boxes available for bulk packaging across our entire product range.
We offer state-of-the-art product design services with the option for custom molds based on order volume, tailored to meet your specific needs.
 
Certifications
Afdd TMA3-40 1P+N Circuit Breaker with B/C/D Tripping Curve
Afdd TMA3-40 1P+N Circuit Breaker with B/C/D Tripping Curve
Afdd TMA3-40 1P+N Circuit Breaker with B/C/D Tripping Curve
Afdd TMA3-40 1P+N Circuit Breaker with B/C/D Tripping Curve
Afdd TMA3-40 1P+N Circuit Breaker with B/C/D Tripping Curve
Afdd TMA3-40 1P+N Circuit Breaker with B/C/D Tripping Curve

 

Packaging & Shipping

Every Timelec product is presented in an elegantly designed white gift box, with one unit per box, ensuring a premium unboxing experience.

Afdd TMA3-40 1P+N Circuit Breaker with B/C/D Tripping Curve
Afdd TMA3-40 1P+N Circuit Breaker with B/C/D Tripping Curve
Afdd TMA3-40 1P+N Circuit Breaker with B/C/D Tripping Curve


For larger orders, our sturdy yellow carton box holds up to 60 units per carton, optimizing both storage and transportation efficiently.

Afdd TMA3-40 1P+N Circuit Breaker with B/C/D Tripping Curve
Throughout our distribution network, we promise secure packaging with:
Timelec's resilient corrugated carton boxes, featuring:

High-quality materials built to withstand the test of time,
Exceptional edge crush resistance ensuring long-lasting durability,
Neutral, sleek black print that offers a sophisticated appearance.

 

Installation Instructions

Afdd TMA3-40 1P+N Circuit Breaker with B/C/D Tripping Curve

Company Profile

Afdd TMA3-40 1P+N Circuit Breaker with B/C/D Tripping CurveAfdd TMA3-40 1P+N Circuit Breaker with B/C/D Tripping CurveAfdd TMA3-40 1P+N Circuit Breaker with B/C/D Tripping CurveAfdd TMA3-40 1P+N Circuit Breaker with B/C/D Tripping Curve

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier