timelec rcbo 40amp 2P TypeAC Eletromagnetic Circuit Breaker rcbo

Product Details
Customization: Available
Breaking Capacity: Low Voltage Circuit Breakers
Operation: Electric Type
Still deciding? Get samples of US$ 7/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2015

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
Experienced Team
The supplier has 6 foreign trading staff(s) and 3 staff(s) with over 6 years of overseas trading experience
to see all verified strength labels (22)
  • timelec rcbo 40amp 2P TypeAC Eletromagnetic Circuit Breaker rcbo
  • timelec rcbo 40amp 2P TypeAC Eletromagnetic Circuit Breaker rcbo
  • timelec rcbo 40amp 2P TypeAC Eletromagnetic Circuit Breaker rcbo
  • timelec rcbo 40amp 2P TypeAC Eletromagnetic Circuit Breaker rcbo
  • timelec rcbo 40amp 2P TypeAC Eletromagnetic Circuit Breaker rcbo
  • timelec rcbo 40amp 2P TypeAC Eletromagnetic Circuit Breaker rcbo
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Detailed Photos
  • Packaging & Shipping
  • Installation Instructions
Overview

Basic Info.

Model NO.
TMRO10-63 Electromagnetic type AC 40A 6kA 2P
Arc-extinguishing Medium
Air
Installation
Fixed
Structure
RCBO
Poles Number
2
Type
Circuit Breaker
Function
Overcurrent Protection, Short circuit
Certification
ISO9001-2000, CE, CB
Standard
IEC 61009-1
Pole
2,4P
Tripping curve
B,C,D
Rated Current (in)
40-63A
Mode
Electromagnetic
Residual Current Type
AC,A
Residual Current (LΔn)
30mA,100mA,300mA
Icn
6KA,10KA
Energy limiting class
3
Electrical Life
20, 000
Mechenical Life
20, 000
keywords
residual current device types
Transport Package
White Gift Box, Yellow Carton Box
Specification
67 X 103 X 78 mm
Trademark
Timelec, OEM / Private Label brands
Origin
China
HS Code
8536200000
Production Capacity
1, 200, 000

Packaging & Delivery

Package Size
6.70cm * 10.30cm * 7.80cm
Package Gross Weight
0.380kg

Product Description

Product Description

RCBO, Residual-current Circuit Breaker with Overcurrent protection, or being called GFCI, Ground Fault Circuit Interrupter, meeting the standard of IEC/BS EN 61009-1, GB16917, is a circuit breaker with the functions of MCB and RCD (RCCB) effectively combined. Timelec RCBO protection against overload, short-circuit and residual current, and has two types depending on its tripping mechanism, respectively ELE (ELEctronic) and ELM (ELectroMagnetic), and has mainly 4 types depending on the waveform and frequency of fault current, namely Type Ac, Type A, Type F, Type B, being selected (mandatorily) in national standards through different countries.
timelec rcbo 40amp 2P TypeAC Eletromagnetic Circuit Breaker rcbo

Product Parameters
Product category CIRCUIT BREAKER
Product type Residual current operated circuit-breakers with integral overcurrent protection (RCBO)
Product model TMRO10-63
Product photo timelec rcbo 40amp 2P TypeAC Eletromagnetic Circuit Breaker rcbo
Business  
information
MOQ: 120pcs
Payment: T/T, L/C
Delivery time: 15-60 days
Loading Port: Ningbo or Shanghai, China
Certification: ISO9001:2015
Logo
:
pad printing, laser printing  (customized design are acceptable)
Unique selling proposition Prevention from overloading and short-circuit currents,
Detection of the earth leakage current.
Protection against indirect contacts and direct contacts.
Preventing fire hazard in cause of circuit fault.
Widly used in residual building and other recombiner distribution boxes
Technical data   Standard IEC 61009-1, GB16917.1
Electrical features Rated current (In) 6A, 10A, 16A, 20A,25A, 32A, 40A, 50A, 63A
Trip curve B, C, D
Model Electronic/Electromagnetic
RCD Type AC, A
Pole 2P, 4P
Rate voltage (Ue) 240V/415V
Insulation voltage(Ui) 500V
Rated frequency 50/60Hz
Energy limiting class 3
Rated residual operating current (IΔn) 30mA, 100mA, 300mA
Rated breaking capacity (Icn) 6KA/10KA
Rated operating short circuit breaking capacity (Ics) 6KA/7.5KA
Rated residual making and breaking capacity(IΔm) 3000A
Rated impulse withstand voltage (Uimp) 4KV
Surge current resistance / at (8/20) μs 3KA
Electrical life 4,000
Pollution degree 2
Mechanical features Mechanical life 20,000
Protection degree IP20
Ambient temperature (with daily averages35°C) -25°C +40°C
Storage temperature -25°C +70°C
Installation Terminal connection type Cable, busbar
Connection capacity (input) 25mm2
Connection capacity (output) 25mm2
Tightening torque (input) 2.5Nm
Tightening torque (output) 2.5Nm
35mm DIN rail
Detailed Photos
timelec rcbo 40amp 2P TypeAC Eletromagnetic Circuit Breaker rcbo

timelec rcbo 40amp 2P TypeAC Eletromagnetic Circuit Breaker rcbo

timelec rcbo 40amp 2P TypeAC Eletromagnetic Circuit Breaker rcbotimelec rcbo 40amp 2P TypeAC Eletromagnetic Circuit Breaker rcbotimelec rcbo 40amp 2P TypeAC Eletromagnetic Circuit Breaker rcbo
Packaging & Shipping

timelec rcbo 40amp 2P TypeAC Eletromagnetic Circuit Breaker rcbo

Installation Instructions

timelec rcbo 40amp 2P TypeAC Eletromagnetic Circuit Breaker rcbotimelec rcbo 40amp 2P TypeAC Eletromagnetic Circuit Breaker rcbotimelec rcbo 40amp 2P TypeAC Eletromagnetic Circuit Breaker rcbotimelec rcbo 40amp 2P TypeAC Eletromagnetic Circuit Breaker rcbo

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier