Modular AFDD Protection Curve C 63A Type B 1P+N 6kA DIN-Rail Mount Breaker

Product Details
Customization: Available
Breaking Capacity: Low Voltage Circuit Breakers
Operation: Electric Type
Still deciding? Get samples of $ !
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company

360° Virtual Tour

Industry-leading Audited Factory

Secured Trading Service
Diamond Member Since 2015

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
to see all verified strength labels (22)
  • Modular AFDD Protection Curve C 63A Type B 1P+N 6kA DIN-Rail Mount Breaker
  • Modular AFDD Protection Curve C 63A Type B 1P+N 6kA DIN-Rail Mount Breaker
  • Modular AFDD Protection Curve C 63A Type B 1P+N 6kA DIN-Rail Mount Breaker
  • Modular AFDD Protection Curve C 63A Type B 1P+N 6kA DIN-Rail Mount Breaker
  • Modular AFDD Protection Curve C 63A Type B 1P+N 6kA DIN-Rail Mount Breaker
  • Modular AFDD Protection Curve C 63A Type B 1P+N 6kA DIN-Rail Mount Breaker
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • FAQ
  • Our Advantages
  • Certifications
  • Packaging & Shipping
  • Installation Instructions
  • Company Profile
Overview

Basic Info.

Model NO.
TMA3-40 6kA C25 TypeAC 1p+N
Speed
High-Speed Circuit Breaker
Arc-extinguishing Medium
Air
Installation
Fixed
Structure
AFDD
Poles Number
1P+N
Type
Circuit Breaker
Function
Overcurrent Protection, RCCB
Certification
VDE, ISO9001-2000, CE, CB, Ukca, NF
Standard
IEC/En 62606 & IEC 61009-1
Pole
1P+N
Tripping Curve
B, C, D
Rated Current (in)
6A, 10A, 16A, 20A, 25A, 32A, 40A
Residual Current Type
Type A, AC
Residual Current (LΔn)
30mA, 100mA, 300mA
Making Breaking Capacity (IΔm)
2, 000A
Icn
6kA
Energy Limiting Class
3
keywords
afdd and rcd
keywords2
afdd circuit breaker
keywords3
arc detection device
Transport Package
White Gift Box, Yellow Carton Box
Specification
115 x 69.6 x 18 mm
Trademark
Timelec, OEM / Private Label brands
Origin
China
HS Code
8536200000
Production Capacity
200, 000

Packaging & Delivery

Package Size
9.00cm * 3.30cm * 13.00cm
Package Gross Weight
0.200kg

Product Description

Product Description

Introducing the AFDD, also known as the Arc-Fault Detection Device, or AFCI, Arc Fault Circuit Interrupter in North America. Designed in strict adherence to the IEC/BS EN 62606 standard, this innovative device ensures optimum safety and reliability.
When it comes to circuit protection, Timelec offers a comprehensive suite: MCB for short-circuit and overload protection, RCD (RCCB) for residual current protection. However, for unparalleled safety, AFDD is indispensable. Statistics reveal that 90% of electrical fires stem from electric arcs, underscoring the essential need for arc protection through AFDD.

 

The Timelec AFDD is a revolutionary AFDD+RCBO, providing an all-encompassing shield against short-circuits, overloads, residual currents, arcs, and over-voltages. It complies with IEC/BS EN 62606 and IEC/BS EN 61009-1 standards, distinguishing harmless arcs from dangerous ones. Notably, it automatically interrupts the circuit upon detecting arcs indicative of loose connections, a leading fire hazard in home wiring.

Product Parameters
Product category CIRCUIT BREAKER
Product type ARC FAULT DETECTION DEVICES (AFDDs)
Product model TMA3-40
Unique selling
proposition
With AFD+RCBO protection
With Over-vol. protection
Total length, 115mm
Technical data   Standard IEC/EN 62606 & IEC 61009-1
Electrical features Rated curret (In) 6A,10A,16A,20A,25A,32A,40A
Trip curve B, C, D
Model Electronic
RCD Type AC, A
Pole 1P+N
Rate voltage (Ue) 240V
Insulation voltage(Ui) 500V
Rated frequency 50Hz
Energy limiting class 3
Rated residual operating current (IΔn) 30mA, 100mA, 300mA
Rated breaking capacity (Icn) 6KA
Rated operating short circuit breaking capacity (Ics) 6KA
Rated residual making and breaking capacity(IΔm) 2000A
Rated impulse withstand voltage (Uimp) 4KV
Surge current resistance / at (8/20) μs 3KA
Overvoltage protection 270V-300V
Electrical life 4,000
Pollution degree 2
Mechanical features Mechanical life 20,000
Protection degree IP20
Ambient temperature (with daily averages35°C) -25°C +40°C
Storage temperature -25°C +70°C
Installation Terminal connection type Cable, busbar
Connection capacity (input) 25mm2
Connection capacity (output) 16mm2
Tightening torque (input) 2.5Nm
Tightening torque (output) 1.2Nm
35mm DIN rail
Modular AFDD Protection Curve C 63A Type B 1P+N 6kA DIN-Rail Mount Breaker
FAQ
Whatarearcs?
Visible plasma discharges caused by electrical current passing through a normally nonconductive medium, such as air.
It is caused when the electrical current ionizes gases in the air.
The temperature can exceed 600 ºC, sufficient to start a fire.
(20% fire associated with electrical distribution or other electrical appliance faults.)
Modular AFDD Protection Curve C 63A Type B 1P+N 6kA DIN-Rail Mount Breaker
Whatcauses arcs?
An arc is created when the electrical current jumps between two conductive material. Most 2 types of arcs are Serial
Arc and Parallel Arc.

Most common causes includes:
1. worn contacts in electrical equipment,
2. damage to insulation,
3. break in cable and loose connections, Etc.
Modular AFDD Protection Curve C 63A Type B 1P+N 6kA DIN-Rail Mount Breaker


What is AFDD?
AFDD is protective device installed in consumer units to provide protection from arc faults.
It uses microprocessor technology to analyze the waveform of the electricity being used to detect any unusual signatures
which would signify an arc on the circuit.

It will cut off the power to the affected circuit and could prevent a fire.
Modular AFDD Protection Curve C 63A Type B 1P+N 6kA DIN-Rail Mount Breaker
Do I need to install AFDD?
Yes, it is highly recommended where there is an increased risk of fire
Modular AFDD Protection Curve C 63A Type B 1P+N 6kA DIN-Rail Mount BreakerModular AFDD Protection Curve C 63A Type B 1P+N 6kA DIN-Rail Mount Breaker
According to IEC 60364 - Electrical installations of buildings Part 4-42 :
Arc Fault Detection Devices are designed to limit fire risks caused by the presence of arc fault currents in the final circuits of a fixed installation.They are installed in electrical switchboards, to protect circuits supplying power sockets and lighting and are especially recommended in cases of renovation.


More specifically, the installation of the AFDD is highly recommended to protect circuits with highest risk of fire, such as:
Protruding cables (risk of knocks)
Outside cables (greater risk of deterioration)
Unprotected cables in secluded areas (like storage rooms)
Aging, deteriorating wiring or wiring for which the connection boxes are inaccessible.
Our Advantages

Timelec AFDD (AFCI) boasts a total length of 115mm, meticulously engineered for efficiency.
Its compact design does not compromise on performance, offering robust protection.

The ultimate choice for comprehensive safety and prevention, Timelec AFDD excels in both domestic and commercial settings.

Timelec offers bespoke customization options:

Printing options: laser or pad, tailored to your branding needs.
Packaging: Enhance value with our elegant white gift box for selected products.
Our yellow carton box serves as a bulk package for the complete range.
Product design: Customizable based on volume, with new moulds available.
 
Certifications
Modular AFDD Protection Curve C 63A Type B 1P+N 6kA DIN-Rail Mount Breaker
Modular AFDD Protection Curve C 63A Type B 1P+N 6kA DIN-Rail Mount Breaker
Modular AFDD Protection Curve C 63A Type B 1P+N 6kA DIN-Rail Mount Breaker
Modular AFDD Protection Curve C 63A Type B 1P+N 6kA DIN-Rail Mount Breaker
Modular AFDD Protection Curve C 63A Type B 1P+N 6kA DIN-Rail Mount Breaker
Modular AFDD Protection Curve C 63A Type B 1P+N 6kA DIN-Rail Mount Breaker

 

Packaging & Shipping

Each white gift box contains 1 piece, perfect for gifting.

Modular AFDD Protection Curve C 63A Type B 1P+N 6kA DIN-Rail Mount Breaker
Modular AFDD Protection Curve C 63A Type B 1P+N 6kA DIN-Rail Mount Breaker
Modular AFDD Protection Curve C 63A Type B 1P+N 6kA DIN-Rail Mount Breaker


Our yellow carton box accommodates 60 pieces, ideal for large orders.

Modular AFDD Protection Curve C 63A Type B 1P+N 6kA DIN-Rail Mount Breaker
As a trusted packaging solution in distribution, Timelec provides:
A durable corrugated carton box:

Premium quality construction,
Superior edge crush resistance,
Neutral black print for a professional finish.

 

Installation Instructions

Modular AFDD Protection Curve C 63A Type B 1P+N 6kA DIN-Rail Mount Breaker

Company Profile

Modular AFDD Protection Curve C 63A Type B 1P+N 6kA DIN-Rail Mount BreakerModular AFDD Protection Curve C 63A Type B 1P+N 6kA DIN-Rail Mount BreakerModular AFDD Protection Curve C 63A Type B 1P+N 6kA DIN-Rail Mount BreakerModular AFDD Protection Curve C 63A Type B 1P+N 6kA DIN-Rail Mount Breaker

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier