1P+N Afdd Circuit Breaker IEC/EN 62606 B/C/D Tripping Curve

Product Details
Customization: Available
Breaking Capacity: Low Voltage Circuit Breakers
Operation: Electric Type
Still deciding? Get samples of $ !
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW PayPal
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company

360° Virtual Tour

Industry-leading Audited Factory

Secured Trading Service
Diamond Member Since 2015

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
to see all verified strength labels (22)
  • 1P+N Afdd Circuit Breaker IEC/EN 62606 B/C/D Tripping Curve
  • 1P+N Afdd Circuit Breaker IEC/EN 62606 B/C/D Tripping Curve
  • 1P+N Afdd Circuit Breaker IEC/EN 62606 B/C/D Tripping Curve
  • 1P+N Afdd Circuit Breaker IEC/EN 62606 B/C/D Tripping Curve
  • 1P+N Afdd Circuit Breaker IEC/EN 62606 B/C/D Tripping Curve
  • 1P+N Afdd Circuit Breaker IEC/EN 62606 B/C/D Tripping Curve
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • FAQ
  • Our Advantages
  • Certifications
  • Packaging & Shipping
  • Installation Instructions
  • Company Profile
Overview

Basic Info.

Model NO.
TMA1-40 1P+N 6kA C40 TypeAC
Speed
High-Speed Circuit Breaker
Arc-extinguishing Medium
Air
Installation
Fixed
Structure
AFDD
Poles Number
1P+N
Type
Circuit Breaker
Function
Overcurrent Protection, RCCB
Certification
VDE, ISO9001-2000, CE, CB, Ukca, NF
Standard
IEC/En 62606 & IEC 61009-1
Pole
1P+N
Tripping Curve
B, C, D
Rated Current (in)
6A, 10A, 16A, 20A, 25A, 32A, 40A
Residual Current Type
Type A, AC
Residual Current (LΔn)
30mA, 100mA, 300mA
Making Breaking Capacity (IΔm)
2, 000A
Icn
6kA
Energy Limiting Class
3
keywords
afdd and rcd
keywords2
afdd circuit breaker
keywords3
arc detection device
Transport Package
White Gift Box, Yellow Carton Box
Specification
115 x 69.6 x 18 mm
Trademark
Timelec, OEM / Private Label brands
Origin
China
HS Code
8536200000
Production Capacity
200, 000

Packaging & Delivery

Package Size
9.00cm * 3.30cm * 1.20cm
Package Gross Weight
0.200kg

Product Description

Product Description

The AFDD, renowned in North America as the Arc Fault Circuit Interrupter (AFCI), is expertly crafted to adhere to the stringent IEC/BS EN 62606 standards, offering an unrivaled level of safety and reliability.
In the realm of circuit protection, Timelec is a pioneer, setting benchmarks with our wide array of protective devices. Our meticulously engineered MCBs offer outstanding short-circuit and overload protection, while our robust RCDs (RCCB) deliver impeccable residual current protection. However, conventional methods fall short in preventing electrical fires, as an astonishing 90% of these fires originate from electric arcs. Enter the AFDD, a vital solution that provides crucial arc protection, safeguarding both lives and valuable properties with unparalleled efficiency.

 

The Timelec AFDD is a state-of-the-art, all-in-one device that seamlessly integrates AFDD and RCBO functionalities, offering comprehensive protection against short-circuits, overloads, residual currents, arcs, and over-voltages. Compliant with IEC/BS EN 62606 and IEC/BS EN 61009-1 standards, our device intelligently discerns between benign and hazardous arcs, ensuring safety by automatically interrupting circuits upon detecting arcs often caused by loose connections. This feature is particularly vital in preventing potentially catastrophic fires in older home wiring systems.

Product Parameters
Product category CIRCUIT BREAKER
Product type ARC FAULT DETECTION DEVICES (AFDDs)
Product model TMA3-40
Unique selling
proposition
With AFD+RCBO protection
With Over-vol. protection
Total length, 115mm
Technical data   Standard IEC/EN 62606 & IEC 61009-1
Electrical features Rated curret (In) 6A,10A,16A,20A,25A,32A,40A
Trip curve B, C, D
Model Electronic
RCD Type AC, A
Pole 1P+N
Rate voltage (Ue) 240V
Insulation voltage(Ui) 500V
Rated frequency 50Hz
Energy limiting class 3
Rated residual operating current (IΔn) 30mA, 100mA, 300mA
Rated breaking capacity (Icn) 6KA
Rated operating short circuit breaking capacity (Ics) 6KA
Rated residual making and breaking capacity(IΔm) 2000A
Rated impulse withstand voltage (Uimp) 4KV
Surge current resistance / at (8/20) μs 3KA
Overvoltage protection 270V-300V
Electrical life 4,000
Pollution degree 2
Mechanical features Mechanical life 20,000
Protection degree IP20
Ambient temperature (with daily averages35°C) -25°C +40°C
Storage temperature -25°C +70°C
Installation Terminal connection type Cable, busbar
Connection capacity (input) 25mm2
Connection capacity (output) 16mm2
Tightening torque (input) 2.5Nm
Tightening torque (output) 1.2Nm
35mm DIN rail
1P+N Afdd Circuit Breaker IEC/EN 62606 B/C/D Tripping Curve
FAQ
Whatarearcs?
Visible plasma discharges caused by electrical current passing through a normally nonconductive medium, such as air.
It is caused when the electrical current ionizes gases in the air.
The temperature can exceed 600 ºC, sufficient to start a fire.
(20% fire associated with electrical distribution or other electrical appliance faults.)
1P+N Afdd Circuit Breaker IEC/EN 62606 B/C/D Tripping Curve
Whatcauses arcs?
An arc is created when the electrical current jumps between two conductive material. Most 2 types of arcs are Serial
Arc and Parallel Arc.

Most common causes includes:
1. worn contacts in electrical equipment,
2. damage to insulation,
3. break in cable and loose connections, Etc.
1P+N Afdd Circuit Breaker IEC/EN 62606 B/C/D Tripping Curve


What is AFDD?
AFDD is protective device installed in consumer units to provide protection from arc faults.
It uses microprocessor technology to analyze the waveform of the electricity being used to detect any unusual signatures
which would signify an arc on the circuit.

It will cut off the power to the affected circuit and could prevent a fire.
1P+N Afdd Circuit Breaker IEC/EN 62606 B/C/D Tripping Curve
Do I need to install AFDD?
Yes, it is highly recommended where there is an increased risk of fire
1P+N Afdd Circuit Breaker IEC/EN 62606 B/C/D Tripping Curve1P+N Afdd Circuit Breaker IEC/EN 62606 B/C/D Tripping Curve
According to IEC 60364 - Electrical installations of buildings Part 4-42 :
Arc Fault Detection Devices are designed to limit fire risks caused by the presence of arc fault currents in the final circuits of a fixed installation.They are installed in electrical switchboards, to protect circuits supplying power sockets and lighting and are especially recommended in cases of renovation.


More specifically, the installation of the AFDD is highly recommended to protect circuits with highest risk of fire, such as:
Protruding cables (risk of knocks)
Outside cables (greater risk of deterioration)
Unprotected cables in secluded areas (like storage rooms)
Aging, deteriorating wiring or wiring for which the connection boxes are inaccessible.
Our Advantages

The Timelec AFDD (AFCI) is designed with a sleek, compact form factor, measuring a mere 115mm in total length.
Remarkably, this compact device delivers outstanding protection and performance, without compromise.

Choosing Timelec AFDD ensures unrivaled, comprehensive protection for both residential and commercial settings, providing clients with unmatched peace of mind.

Timelec offers a broad spectrum of customization options:

Branding options include precise laser or pad printing for detailed customization.
Elevate product perception with our sophisticated packaging, featuring elegant white gift boxes for select items.
For larger orders, our robust yellow carton boxes ensure efficient bulk packaging across the entire product line.
Harness our innovative design services, with the option for new molds based on order quantities.
 
Certifications
1P+N Afdd Circuit Breaker IEC/EN 62606 B/C/D Tripping Curve
1P+N Afdd Circuit Breaker IEC/EN 62606 B/C/D Tripping Curve
1P+N Afdd Circuit Breaker IEC/EN 62606 B/C/D Tripping Curve
1P+N Afdd Circuit Breaker IEC/EN 62606 B/C/D Tripping Curve
1P+N Afdd Circuit Breaker IEC/EN 62606 B/C/D Tripping Curve
1P+N Afdd Circuit Breaker IEC/EN 62606 B/C/D Tripping Curve

 

Packaging & Shipping

Each individual product is gracefully encased in a pristine white gift box: one piece per box, enhancing the unboxing experience.

1P+N Afdd Circuit Breaker IEC/EN 62606 B/C/D Tripping Curve
1P+N Afdd Circuit Breaker IEC/EN 62606 B/C/D Tripping Curve
1P+N Afdd Circuit Breaker IEC/EN 62606 B/C/D Tripping Curve


For bulk orders, our sturdy yellow carton boxes are designed to hold 60 pieces per carton, maximizing storage and transport efficiency.

1P+N Afdd Circuit Breaker IEC/EN 62606 B/C/D Tripping Curve
Within our sophisticated distribution network, we ensure products are securely packaged with:
Timelec's robust and durable corrugated carton boxes offer:

Premium materials of the highest quality,
Exceptional resistance to edge crushing for added durability,
A sleek, neutral black print for a sophisticated appearance.

 

Installation Instructions

1P+N Afdd Circuit Breaker IEC/EN 62606 B/C/D Tripping Curve

Company Profile

1P+N Afdd Circuit Breaker IEC/EN 62606 B/C/D Tripping Curve1P+N Afdd Circuit Breaker IEC/EN 62606 B/C/D Tripping Curve1P+N Afdd Circuit Breaker IEC/EN 62606 B/C/D Tripping Curve1P+N Afdd Circuit Breaker IEC/EN 62606 B/C/D Tripping Curve

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier