Our SPD Surge Protective Devices are the pinnacle of safeguarding technology, standing ready to defend your precious electronics from the unpredictable wrath of voltage spikes. Imagine a formidable lightning strike that releases an overwhelming surge of energy, potentially causing extensive damage. However, it's crucial to understand that while such large surge events are dramatic, they only account for 20% of all transient surges. A silent, yet significant 80% arise internally, gradually undermining the integrity of sensitive electronic equipment over time. Protect against this persistent threat with our state-of-the-art solution.
A power surge is a brief but intense overload of voltage that can severely threaten electrical devices, frequently leading to their premature failure. These surges are notorious for causing extensive damage, impacting the functionality and longevity of numerous household essentials, including:
NEW 2020 National Electrical Code Requirements
The innovative 2020 National Electrical Code mandates that all new and remodeled homes must be equipped with Listed and Approved Type 1 or Type 2 Surge Protective Devices. This groundbreaking regulation sets a new benchmark for electrical safety and protection.
Type 1:
A permanently connected Surge Protective Device offering robust defense against both external and internal surges. It provides flexible installation options, suitable for either the interior or exterior of your home, ensuring comprehensive protection.
Type 2:
A formidable, permanently connected Surge Protective Device, designed for strategic placement within or near the breaker box. It effectively mitigates both internal and external surge threats, fortifying your home's electrical system.
Type 3:
Offering enhanced protection, the point-of-use Surge Protective Device provides an added layer of defense, especially when combined with Type 1 or Type 2 SPDs. This ensures full compliance with the 2020 code requirements.
For the ultimate in comprehensive protection, utilize a combination of Type 1, 2, and 3 SPDs, ensuring your home is fortified against any and all electrical anomalies with unwavering reliability.
Max Continuous Operating Voltage | Ucpv | 500VDC | 600VDC | 1000VDC | 1500VDC | ||||||
Nominal Discharge Current | In | 20kA | 20kA | 20kA | 20kA | ||||||
Max Discharge Current | lmax | 40kA | 40 kA | 40kA | 40kA | ||||||
Protection level | Up | 2.8kV | 3.0kV | 3.5kV | 5.5 kV | ||||||
Rated shortcircuit current | IscCI | 100A | |||||||||
lcpv | 0.2 mA | ||||||||||
Connection mode | paralle | ||||||||||
Response Time | tA | 25ns | |||||||||
Back up fuse | LT-SSD40 | ||||||||||
Remotecommunication | With | ||||||||||
Remote communication connection | 1411:NO,1112:NC | ||||||||||
Remote contact rated current | 220V/0.5A | ||||||||||
Associateddisconnectors | |||||||||||
Thermal disconnector | internal | ||||||||||
Fuses | Fuses type gG100A | ||||||||||
ground fault breaker | None | ||||||||||
Mechnicalcharacteristics | |||||||||||
Connection | By screw terminals:6-35mm | ||||||||||
Terminal Screw Torque | 2.5 Nm | ||||||||||
RecommendedCable cross Section | ≥16mm² | ||||||||||
Insertwire length | 15mm | ||||||||||
Mounting | DIN rail 35mm (EN60715) | ||||||||||
Degree of Protection | IP20 | ||||||||||
Housing | PBT | ||||||||||
Flame retardant grade | UL94 V0 | ||||||||||
Operating temperature | -40ºC~+70ºC | ||||||||||
Operatingrelative humidity | 5%-95% | ||||||||||
Working atmospheric pressure | 70kPa~106kPa | ||||||||||
Connection | By screw terminals:6-35mm |
Selection of SPD:
Selecting the right Surge Protection Device (SPD) is an essential step in fortifying your power distribution system. To ensure your building's electrical installation is optimally protected, consider the defining characteristics of the lightning protection system.
Additional key characteristics for SPD selection are generally predetermined for a specific electrical setup.
This sub-sectionDesign of the Electrical Installation Protection SystemThis section delves into the comprehensive criteria required for selecting a protection system. It evaluates installation features, the devices needing protection, and the environmental conditions.
Location and Types of SPD:
Connection of SPD:
To achieve optimal protection levels, ensure SPD connections to loads are as brief as possible. This helps reduce the installed voltage protection level (Up) at the equipment's terminals.
Maintain the total length of SPD connections to both the network and the earth terminal block to under 50 cm for maximum efficiency.
SPD Enclosures: Choose between SPD in a plastic or metal enclosure for your specific needs.
RED: Replace