Advanced DC SPD 275V / 255V, 20kA In, Maximum 40kA Imax

Product Details
Customization: Available
Type: Power Source Arrester
Structure: Zinc Oxide Arrester
Still deciding? Get samples of $ !
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company

360° Virtual Tour

Industry-leading Audited Factory

Secured Trading Service
Diamond Member Since 2015

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
to see all verified strength labels (22)
  • Advanced DC SPD 275V / 255V, 20kA In, Maximum 40kA Imax
  • Advanced DC SPD 275V / 255V, 20kA In, Maximum 40kA Imax
  • Advanced DC SPD 275V / 255V, 20kA In, Maximum 40kA Imax
  • Advanced DC SPD 275V / 255V, 20kA In, Maximum 40kA Imax
  • Advanced DC SPD 275V / 255V, 20kA In, Maximum 40kA Imax
  • Advanced DC SPD 275V / 255V, 20kA In, Maximum 40kA Imax
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Installation Instructions
Overview

Basic Info.

Model NO.
TMSPD7
Installation
Tandem Arrester
Application
AC/DC System
Size
Small
Operation Voltage
Low Voltage
Shape
Cuboid
Material
PBT Fireproof
Certification
ROHS, ISO9001, CE
Brand
Timelec
Uc
275V / 255V
In
20kA
Imax
40kA
Up
1.5kV
IEC
IEC61643-11
IP
IP20
Protection
Class II, T2
Transport Package
Carton Box
Specification
18mm
Trademark
Timelec, OEM / Private Label brands
Origin
China
HS Code
853620
Production Capacity
1000000

Packaging & Delivery

Package Size
4.60cm * 7.80cm * 3.60cm
Package Gross Weight
0.190kg

Product Description

Product Description

Our SPD Surge Protective Devices are the pinnacle of safeguarding technology, standing ready to defend your precious electronics from the unpredictable wrath of voltage spikes. Imagine a formidable lightning strike that releases an overwhelming surge of energy, potentially causing extensive damage. However, it's crucial to understand that while such large surge events are dramatic, they only account for 20% of all transient surges. A silent, yet significant 80% arise internally, gradually undermining the integrity of sensitive electronic equipment over time. Protect against this persistent threat with our state-of-the-art solution.


A power surge is a brief but intense overload of voltage that can severely threaten electrical devices, frequently leading to their premature failure. These surges are notorious for causing extensive damage, impacting the functionality and longevity of numerous household essentials, including:

  • Heating and Air Conditioning Systems
  • Washers and Dryers
  • Water Heaters
  • Ranges & Refrigerators
  • Lighting
  • Entertainment Systems

NEW 2020 National Electrical Code Requirements
The innovative 2020 National Electrical Code mandates that all new and remodeled homes must be equipped with Listed and Approved Type 1 or Type 2 Surge Protective Devices. This groundbreaking regulation sets a new benchmark for electrical safety and protection.

Type 1:
A permanently connected Surge Protective Device offering robust defense against both external and internal surges. It provides flexible installation options, suitable for either the interior or exterior of your home, ensuring comprehensive protection.

Type 2:
A formidable, permanently connected Surge Protective Device, designed for strategic placement within or near the breaker box. It effectively mitigates both internal and external surge threats, fortifying your home's electrical system.

Type 3:
Offering enhanced protection, the point-of-use Surge Protective Device provides an added layer of defense, especially when combined with Type 1 or Type 2 SPDs. This ensures full compliance with the 2020 code requirements.

For the ultimate in comprehensive protection, utilize a combination of Type 1, 2, and 3 SPDs, ensuring your home is fortified against any and all electrical anomalies with unwavering reliability.

Product Parameters
Max Continuous Operating Voltage Ucpv 500VDC 600VDC 1000VDC 1500VDC
Nominal Discharge Current In 20kA 20kA 20kA 20kA
Max Discharge Current lmax 40kA 40 kA 40kA 40kA
Protection level Up 2.8kV 3.0kV 3.5kV 5.5 kV
Rated shortcircuit current IscCI 100A
lcpv 0.2 mA
Connection mode paralle
Response Time tA 25ns
Back up fuse LT-SSD40
Remotecommunication With
Remote communication connection 1411:NO,1112:NC
Remote contact rated current 220V/0.5A
Associateddisconnectors
Thermal disconnector internal
Fuses Fuses type gG100A
ground fault breaker None
Mechnicalcharacteristics
Connection By screw terminals:6-35mm
Terminal Screw Torque 2.5 Nm
RecommendedCable cross Section 16mm²
Insertwire length 15mm
Mounting DIN rail 35mm (EN60715)
Degree of Protection IP20
Housing PBT
Flame retardant grade UL94 V0
Operating temperature -40ºC~+70ºC
Operatingrelative humidity 5%-95%
Working atmospheric pressure 70kPa~106kPa
Connection By screw terminals:6-35mm
Installation Instructions

Selection of SPD:
Selecting the right Surge Protection Device (SPD) is an essential step in fortifying your power distribution system. To ensure your building's electrical installation is optimally protected, consider the defining characteristics of the lightning protection system.

  • SPD
    • Quantity of SPD
    • Type
    • Evaluating the exposure level is vital to determine the SPD's maximum discharge capacity, referred to as Imax.
  • Short Circuit Protection Device
    • Maximum discharge current, or Imax;
    • Short-circuit current, or Isc, at the installation point.
Advanced DC SPD 275V / 255V, 20kA In, Maximum 40kA Imax

Additional key characteristics for SPD selection are generally predetermined for a specific electrical setup.

  • Number of poles in SPD;
  • Voltage protection level, Up;
  • Operating voltage, Uc.

This sub-sectionDesign of the Electrical Installation Protection SystemThis section delves into the comprehensive criteria required for selecting a protection system. It evaluates installation features, the devices needing protection, and the environmental conditions.

Location and Types of SPD:
Advanced DC SPD 275V / 255V, 20kA In, Maximum 40kA Imax

Connection of SPD:
To achieve optimal protection levels, ensure SPD connections to loads are as brief as possible. This helps reduce the installed voltage protection level (Up) at the equipment's terminals.

Maintain the total length of SPD connections to both the network and the earth terminal block to under 50 cm for maximum efficiency.

Advanced DC SPD 275V / 255V, 20kA In, Maximum 40kA Imax
Advanced DC SPD 275V / 255V, 20kA In, Maximum 40kA Imax

SPD Enclosures: Choose between SPD in a plastic or metal enclosure for your specific needs.

Advanced DC SPD 275V / 255V, 20kA In, Maximum 40kA Imax
Advanced DC SPD 275V / 255V, 20kA In, Maximum 40kA Imax

 

RED: Replace
A RED indicator signals that the SPD has reached its operational limit and must be immediately replaced to maintain effective protection.
Advanced DC SPD 275V / 255V, 20kA In, Maximum 40kA Imax

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier