Advanced SPD Solar Surge Protector 230V, 20kA In, 40kA Imax

Product Details
Customization: Available
Type: Power Source Arrester
Structure: Valve Type Arrester
Still deciding? Get samples of $ !
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW PayPal
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company

360° Virtual Tour

Industry-leading Audited Factory

Secured Trading Service
Diamond Member Since 2015

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
to see all verified strength labels (22)
  • Advanced SPD Solar Surge Protector 230V, 20kA In, 40kA Imax
  • Advanced SPD Solar Surge Protector 230V, 20kA In, 40kA Imax
  • Advanced SPD Solar Surge Protector 230V, 20kA In, 40kA Imax
  • Advanced SPD Solar Surge Protector 230V, 20kA In, 40kA Imax
  • Advanced SPD Solar Surge Protector 230V, 20kA In, 40kA Imax
  • Advanced SPD Solar Surge Protector 230V, 20kA In, 40kA Imax
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Installation Instructions
Overview

Basic Info.

Model NO.
TMSPD1
Installation
Parallel Arrester
Application
AC/DC System
Size
Small
Operation Voltage
Low Voltage
Shape
Cuboid
Material
ZnO
Certification
ISO9001
Brand
Timelec
Uc
230V
In
20kA
Imax
40kA
Up
1.5kV
IEC
IEC61643-11
IP
IP20
Protection
Class II, T2
Transport Package
Carton Box
Specification
36*69*91mm
Trademark
Timelec, OEM / Private Label brands
Origin
China
HS Code
853620
Production Capacity
1000000

Packaging & Delivery

Package Size
4.00cm * 9.30cm * 7.50cm
Package Gross Weight
0.300kg

Product Description

Product Description

Our Surge Protective Devices (SPDs) are expertly engineered to safeguard your valuable equipment from damaging transient surges. Large surge events, such as lightning strikes, can unleash hundreds of thousands of volts, resulting in catastrophic or sporadic equipment failure. Lightning and utility anomalies contribute to just 20% of these events. The remaining 80% arise internally, often unnoticed yet frequent, causing gradual deterioration of sensitive electronics.

Product Features
1. Robust 1P+N phase protection for both AC and DC systems

2. Featuring a user-friendly pluggable module for seamless installation and effortless maintenance

3. Remarkable high discharge capacity paired with rapid response time

4. Equipped with dual thermal disconnection devices for enhanced protection reliability

5. A proactive green window alerts you of faults and facilitates remote alarm control simultaneously


A power surge is a fleeting overvoltage occurrence, known for damaging electrical devices and frequently causing equipment failure. Such surges can harm and diminish the lifespan of:

  • State-of-the-art Heating and Air Conditioning Systems
  • Modern Washers and Dryers
  • Efficient Water Heaters
  • Versatile Ranges & Refrigerators
  • Innovative Lighting solutions
  • Cutting-edge Entertainment Systems

As per the National Electrical Manufacturers Association, the typical household houses around $15,000 worth of equipment susceptible to surge damage.

Common Causes of Surges:
A significant 80% of surges are attributed to internal origins

Internal Sources include:

  • Switching large appliances on or off
  • Issues like faulty wiring or loose connections
  • Overloaded circuits, short circuits, or ground faults
  • Power recovery scenarios

External Sources encompass:

  • Natural phenomena such as lightning
  • Compromised power lines
  • Utility power grid switching activities


NEW 2020 National Electrical Code Requirements
Mandates that all new and renovated residences integrate Listed and Approved Type 1 or Type 2 Surge Protective Devices.

Type 1 SPD:
A permanently connected SPD, effective against both external and internal surges; versatile for indoor or outdoor installation.

Type 2 SPD:
A permanently connected SPD placed in or next to the breaker box, securing protection from both internal and external surges.

Type 3 SPD:
An additional layer of defense: a Point-of-use SPD, which must work alongside Type 1 or Type 2 SPDs to comply with 2020 code mandates.

For the utmost protection, utilize a combination of Type 1, 2, and 3 SPDs.

Product Parameters
Product category Surge protection
Product type SURGE PROTECTIVE DEVICE
Product model HLSPD,SPD,TMSPD2
Unique selling proposition ·TMSPD1 SPD are suit for IT,TT,TN-C,TN-S,TN-C-S and low-voltage AC power distribution system, protect both direct and indirect lighting impulse and other transient over voltage.
·TMSPD1 surge protection device have high energy MOV chip, fast response speed.
·Products comply with IEC61643-1.2005, IEC61643-11.2011 standard.
Technical data Type of SPD according to EN 61643-11 Type 2
SPD according to IEC 61643-1 Class II
Nominal a.c voltage( Un) 230V
Max continuous operating a.c voltage (Uc) 275/320/385/440V
Nominal discharge current (In 8/20|jS) 10/20KA
Max. discharge current (Imax 8/20pS) 20/40KA
Voltage protection level (Up) <1.3/1.4/1.5/1.8/2.2KV
Response time (tA) <25ns
Operating temperature range (Tu) -40°C +80°C
Operating state/fault indication Green/red
Cross-section area (min) 4mm²
Cross-section area (Max) 16mm²
For mounting on 35mm DIN rail acc to EN60715
Degree of protection IP20
Terminal screw torque 2.5N·m
Approvals TUV
 
Installation Instructions

Selection of SPD:
To ensure top-notch protection for your electrical systems, the fundamental attributes to consider in defining a lightning protection system and selecting the ideal SPD for a building's electrical installation include:

  • SPD
    • Quantity of SPD units required
    • Type
    • Exposure level assessment is crucial to determine the SPD's maximum discharge current, Imax.
  • Short circuit protection device
    • Maximum discharge current, Imax;
    • Short-circuit current Isc, measured at the installation point.
Advanced SPD Solar Surge Protector 230V, 20kA In, 40kA Imax

Other essential characteristics for choosing an SPD are pre-established for the electrical installation.

  • Number of poles in SPD;
  • Voltage protection level, Up;
  • Operating voltage, Uc.

This sub-section Design of the electrical installation protection system elaborates on the criteria necessary for selecting the optimal protection system, factoring in the specific features of the installation, the equipment needing safeguarding, and the surrounding environment.

Location and types of SPD:
Advanced SPD Solar Surge Protector 230V, 20kA In, 40kA Imax

Connection of SPD:
For maximum efficiency, connections of an SPD to the loads must be kept as short as possible, significantly reducing the voltage protection level (installed Up) at the terminals of the protected equipment.

Ensure that the total length of SPD connections to both the network and the earth terminal block remains below 50 cm to maintain optimal performance.

Advanced SPD Solar Surge Protector 230V, 20kA In, 40kA Imax
Advanced SPD Solar Surge Protector 230V, 20kA In, 40kA Imax

SPD in plastic enclosure SPD in metal enclosure

Advanced SPD Solar Surge Protector 230V, 20kA In, 40kA Imax
Advanced SPD Solar Surge Protector 230V, 20kA In, 40kA Imax

 

RED: Replace
Once the indicator displays RED, it signifies that the product must be promptly replaced to ensure continued reliability.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier