[manufacture] 230V Surge Protection Device, 20kA In, 40kA Imax

Product Details
Customization: Available
Type: Power Source Arrester
Structure: Valve Type Arrester
Still deciding? Get samples of $ !
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company

360° Virtual Tour

Industry-leading Audited Factory

Secured Trading Service
Diamond Member Since 2015

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
to see all verified strength labels (22)
  • [manufacture] 230V Surge Protection Device, 20kA In, 40kA Imax
  • [manufacture] 230V Surge Protection Device, 20kA In, 40kA Imax
  • [manufacture] 230V Surge Protection Device, 20kA In, 40kA Imax
  • [manufacture] 230V Surge Protection Device, 20kA In, 40kA Imax
  • [manufacture] 230V Surge Protection Device, 20kA In, 40kA Imax
  • [manufacture] 230V Surge Protection Device, 20kA In, 40kA Imax
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Installation Instructions
Overview

Basic Info.

Model NO.
TMSPD1
Installation
Parallel Arrester
Application
AC/DC System
Size
Small
Operation Voltage
Low Voltage
Shape
Cuboid
Material
ZnO
Certification
ISO9001
Brand
Timelec
Uc
230V
In
20kA
Imax
40kA
Up
1.5kV
IEC
IEC61643-11
IP
IP20
Protection
Class II, T2
Transport Package
Carton Box
Specification
36*69*91mm
Trademark
Timelec, OEM / Private Label brands
Origin
China
HS Code
853620
Production Capacity
1000000

Packaging & Delivery

Package Size
4.00cm * 9.30cm * 7.50cm
Package Gross Weight
0.300kg

Product Description

Product Description

Introducing our cutting-edge Surge Protective Devices, meticulously engineered to fortify your electrical systems against the onslaught of transient surge conditions. These powerful devices provide an impenetrable shield against massive single surge events, such as lightning strikes, which can unleash a torrent of hundreds of thousands of volts, threatening to compromise your equipment either immediately or over time. Remarkably, while lightning and utility power fluctuations account for a mere 20% of transient surges, a staggering 80% are self-generated within your own facilities. Although these internal surges often exhibit lower intensity, their persistent occurrence poses a silent but formidable threat, gradually undermining the performance and longevity of your sophisticated electronic assets.

Product Features
1. Versatile 1P+N phase protection adaptable for both AC and DC systems, ensuring all-encompassing safety.

2. User-friendly pluggable module design that guarantees effortless installation and seamless maintenance.

3. Unparalleled high discharge capacity combined with lightning-fast response time for premium surge protection.

4. Outfitted with dual thermal disconnection devices, offering superior reliability and protection.

5. Pioneering green window indicator that signals faults instantly, enhanced by remote alarm control for active monitoring.


A power surge is a fleeting overvoltage episode that jeopardizes electrical devices, frequently leading to equipment malfunction and diminished lifespan. Surges are infamous for their capacity to inflict damage and curtail the durability of various household systems and appliances, including:

  • Heating and Air Conditioning Systems
  • Washers and Dryers
  • Water Heaters
  • Ranges & Refrigerators
  • Lighting
  • Entertainment Systems

Did you know that, according to the National Electrical Manufacturers Association, the typical home harbors approximately $15,000 worth of equipment vulnerable to surge-induced damage?

Common Causes of Surges:
Experts estimate that a significant 80% of surges originate from internal sources within the property.

Internal Sources:

  • Sudden surges commonly occur when large appliances are activated or deactivated.
  • Faulty wiring or loose connections can also precipitate surge events.
  • Overloaded circuits, short circuits, or ground faults are prevalent internal surge catalysts.
  • Power recovery incidents can also provoke surges.

External Sources:

  • Lightning strikes are a quintessential example of external sources causing surges.
  • Physical damage to power lines can incite surge occurrences.
  • Utility power grid switching is another potential external surge source.


NEW 2020 National Electrical Code Requirements
The newly established 2020 code mandates that every new and remodeled residence must incorporate Listed and Approved Type 1 or Type 2 Surge Protective Devices, ensuring unrivaled safety and adherence to standards.

Type 1:
A permanently connected Surge Protective Device, Type 1 delivers comprehensive protection against both external and internal surges and can be strategically installed inside or outside the premises.

Type 2:
This permanently connected Surge Protective Device is strategically placed in, or adjacent to, the breaker box, delivering defense against internal or external surges.

Type 3:
For supplementary safeguarding, the Type 3 is a point-of-use Surge Protective Device, mandatorily used alongside Type 1 or Type 2 SPDs to fulfill the 2020 code prerequisites, providing unmatched protection.

For the utmost protection, it is strongly recommended to deploy Type 1, 2, and 3 SPDs concurrently, ensuring an invincible level of defense against surges.

Product Parameters
Product category Surge protection
Product type SURGE PROTECTIVE DEVICE
Product model HLSPD,SPD,TMSPD2
Unique selling proposition ·TMSPD1 SPD are suit for IT,TT,TN-C,TN-S,TN-C-S and low-voltage AC power distribution system, protect both direct and indirect lighting impulse and other transient over voltage.
·TMSPD1 surge protection device have high energy MOV chip, fast response speed.
·Products comply with IEC61643-1.2005, IEC61643-11.2011 standard.
Technical data Type of SPD according to EN 61643-11 Type 2
SPD according to IEC 61643-1 Class II
Nominal a.c voltage( Un) 230V
Max continuous operating a.c voltage (Uc) 275/320/385/440V
Nominal discharge current (In 8/20|jS) 10/20KA
Max. discharge current (Imax 8/20pS) 20/40KA
Voltage protection level (Up) <1.3/1.4/1.5/1.8/2.2KV
Response time (tA) <25ns
Operating temperature range (Tu) -40°C +80°C
Operating state/fault indication Green/red
Cross-section area (min) 4mm²
Cross-section area (Max) 16mm²
For mounting on 35mm DIN rail acc to EN60715
Degree of protection IP20
Terminal screw torque 2.5N·m
Approvals TUV
 
Installation Instructions

Selection of SPD:
For an unparalleled power distribution system, understanding the essential characteristics that define a lightning protection system is imperative. Selecting the right Surge Protection Device (SPD) is crucial to safeguarding electrical installations within a building. Consider the following fundamental factors:

  • SPD
    • Quantity of SPD
    • Type
    • The level of exposure is a determining factor for the SPD's maximum discharge current, known as Imax, ensuring optimal protection.
  • Short Circuit Protection Device
    • Maximum discharge current, Imax;
    • Short-circuit current, Isc at the installation point.
[manufacture] 230V Surge Protection Device, 20kA In, 40kA Imax

Predefined characteristics for selecting an SPD allow for seamless integration into an electrical installation, ensuring optimal functionality and protection.

  • Number of poles in SPD;
  • Voltage protection level, Up;
  • Operating voltage, Uc.

This Sub-sectionDesign of the Electrical Installation Protection SystemThis segment delves deeply into the criteria for selecting the protection system tailored to the installation's characteristics, the equipment needing protection, and the environmental context.

Location and Types of SPD:
[manufacture] 230V Surge Protection Device, 20kA In, 40kA Imax

Connection of SPD:
Optimize SPD connections by minimizing their length to effectively reduce the voltage protection level (installed Up) at the terminals of the devices being protected.

Ensure that the total length of SPD connections to both the network and the earth terminal block does not exceed 50 cm, maintaining effective protection.

[manufacture] 230V Surge Protection Device, 20kA In, 40kA Imax
[manufacture] 230V Surge Protection Device, 20kA In, 40kA Imax

SPD in a plastic enclosure SPD in a metal enclosure

[manufacture] 230V Surge Protection Device, 20kA In, 40kA Imax
[manufacture] 230V Surge Protection Device, 20kA In, 40kA Imax

 

RED: Replace
If the indicator shows RED, it is crucial to replace the product immediately to ensure continued optimal protection.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier