TMA3-40 1P+N Circuit Breaker with B/C/D Tripping Curve

Product Details
Customization: Available
Breaking Capacity: Low Voltage Circuit Breakers
Operation: Electric Type
Still deciding? Get samples of $ !
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW PayPal
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company

360° Virtual Tour

Industry-leading Audited Factory

Secured Trading Service
Diamond Member Since 2015

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
to see all verified strength labels (22)
  • TMA3-40 1P+N Circuit Breaker with B/C/D Tripping Curve
  • TMA3-40 1P+N Circuit Breaker with B/C/D Tripping Curve
  • TMA3-40 1P+N Circuit Breaker with B/C/D Tripping Curve
  • TMA3-40 1P+N Circuit Breaker with B/C/D Tripping Curve
  • TMA3-40 1P+N Circuit Breaker with B/C/D Tripping Curve
  • TMA3-40 1P+N Circuit Breaker with B/C/D Tripping Curve
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • FAQ
  • Our Advantages
  • Certifications
  • Packaging & Shipping
  • Installation Instructions
  • Company Profile
Overview

Basic Info.

Model NO.
TMA3-40 6kA C25 TypeAC 1p+N
Speed
High-Speed Circuit Breaker
Arc-extinguishing Medium
Air
Installation
Fixed
Structure
AFDD
Poles Number
1P+N
Type
Circuit Breaker
Function
Overcurrent Protection, RCCB
Certification
VDE, ISO9001-2000, CE, CB, Ukca, NF
Standard
IEC/En 62606 & IEC 61009-1
Pole
1P+N
Tripping Curve
B, C, D
Rated Current (in)
6A, 10A, 16A, 20A, 25A, 32A, 40A
Residual Current Type
Type A, AC
Residual Current (LΔn)
30mA, 100mA, 300mA
Making Breaking Capacity (IΔm)
2, 000A
Icn
6kA
Energy Limiting Class
3
keywords
afdd and rcd
keywords2
afdd circuit breaker
keywords3
arc detection device
Transport Package
White Gift Box, Yellow Carton Box
Specification
115 x 69.6 x 18 mm
Trademark
Timelec, OEM / Private Label brands
Origin
China
HS Code
8536200000
Production Capacity
200, 000

Packaging & Delivery

Package Size
9.00cm * 3.30cm * 13.00cm
Package Gross Weight
0.200kg

Product Description

Product Description

Our AFDD, or Arc-Fault Detection Device, synonymous with AFCI (Arc Fault Circuit Interrupter) in the United States, stands as a testament to safety excellence, meeting the rigorous IEC/BS EN 62606 standard. It is a formidable shield for modern electrical systems, providing unmatched protection.
In the dynamic world of circuit protection, Timelec delivers exceptional MCBs to guard against the perils of short-circuits and overloads, while RCCBs offer top-tier residual current protection. Yet, these alone are not enough for total security. Startling figures show that a staggering 90% of electrical fires are due to elusive electric arcs, underscoring the indispensable role of AFDD devices in shielding against such dangerous arc-related incidents.

 

The Timelec AFDD represents a revolutionary fusion of AFDD and RCBO technology, establishing a new standard in protection against short-circuit, overload, residual current, arc, and over-voltage threats. It rigorously complies with the stringent IEC/BS EN 62606 and IEC/BS EN 61009-1 standards, with an expert ability to differentiate harmless arcs from those that present serious danger. Upon detecting an electric arc-a common sign of loose home wiring connections-it quickly disrupts the circuit, preventing the escalation that can lead to devastating house fires.

Product Parameters
Product category CIRCUIT BREAKER
Product type ARC FAULT DETECTION DEVICES (AFDDs)
Product model TMA3-40
Unique selling
proposition
With AFD+RCBO protection
With Over-vol. protection
Total length, 115mm
Technical data   Standard IEC/EN 62606 & IEC 61009-1
Electrical features Rated curret (In) 6A,10A,16A,20A,25A,32A,40A
Trip curve B, C, D
Model Electronic
RCD Type AC, A
Pole 1P+N
Rate voltage (Ue) 240V
Insulation voltage(Ui) 500V
Rated frequency 50Hz
Energy limiting class 3
Rated residual operating current (IΔn) 30mA, 100mA, 300mA
Rated breaking capacity (Icn) 6KA
Rated operating short circuit breaking capacity (Ics) 6KA
Rated residual making and breaking capacity(IΔm) 2000A
Rated impulse withstand voltage (Uimp) 4KV
Surge current resistance / at (8/20) μs 3KA
Overvoltage protection 270V-300V
Electrical life 4,000
Pollution degree 2
Mechanical features Mechanical life 20,000
Protection degree IP20
Ambient temperature (with daily averages35°C) -25°C +40°C
Storage temperature -25°C +70°C
Installation Terminal connection type Cable, busbar
Connection capacity (input) 25mm2
Connection capacity (output) 16mm2
Tightening torque (input) 2.5Nm
Tightening torque (output) 1.2Nm
35mm DIN rail
TMA3-40 1P+N Circuit Breaker with B/C/D Tripping Curve
FAQ
Whatarearcs?
Visible plasma discharges caused by electrical current passing through a normally nonconductive medium, such as air.
It is caused when the electrical current ionizes gases in the air.
The temperature can exceed 600 ºC, sufficient to start a fire.
(20% fire associated with electrical distribution or other electrical appliance faults.)
TMA3-40 1P+N Circuit Breaker with B/C/D Tripping Curve
Whatcauses arcs?
An arc is created when the electrical current jumps between two conductive material. Most 2 types of arcs are Serial
Arc and Parallel Arc.

Most common causes includes:
1. worn contacts in electrical equipment,
2. damage to insulation,
3. break in cable and loose connections, Etc.
TMA3-40 1P+N Circuit Breaker with B/C/D Tripping Curve


What is AFDD?
AFDD is protective device installed in consumer units to provide protection from arc faults.
It uses microprocessor technology to analyze the waveform of the electricity being used to detect any unusual signatures
which would signify an arc on the circuit.

It will cut off the power to the affected circuit and could prevent a fire.
TMA3-40 1P+N Circuit Breaker with B/C/D Tripping Curve
Do I need to install AFDD?
Yes, it is highly recommended where there is an increased risk of fire
TMA3-40 1P+N Circuit Breaker with B/C/D Tripping CurveTMA3-40 1P+N Circuit Breaker with B/C/D Tripping Curve
According to IEC 60364 - Electrical installations of buildings Part 4-42 :
Arc Fault Detection Devices are designed to limit fire risks caused by the presence of arc fault currents in the final circuits of a fixed installation.They are installed in electrical switchboards, to protect circuits supplying power sockets and lighting and are especially recommended in cases of renovation.


More specifically, the installation of the AFDD is highly recommended to protect circuits with highest risk of fire, such as:
Protruding cables (risk of knocks)
Outside cables (greater risk of deterioration)
Unprotected cables in secluded areas (like storage rooms)
Aging, deteriorating wiring or wiring for which the connection boxes are inaccessible.
Our Advantages

The Timelec AFDD (AFCI) is a marvel of design precision with a total length of just 115mm, harmonizing compactness with high performance.
Despite its compact size, it is meticulously crafted to ensure unparalleled efficiency and effectiveness.

For those who demand the utmost in safety and protection, this device is the ultimate choice for both residential and commercial settings, offering impeccable safeguarding for every environment.

Timelec presents tailored customization options:

Print options: Select from laser or pad printing to create personalized branding that reflects your unique identity.
Packaging solutions: Choose an elegant white gift box for selected products, enhancing perceived value and sophistication;
or opt for a practical yellow carton box, perfect for an extensive range and bulk packaging needs.
Product design: Explore limitless customization opportunities, with new mould creation available for large volume orders.
 
Certifications
TMA3-40 1P+N Circuit Breaker with B/C/D Tripping Curve
TMA3-40 1P+N Circuit Breaker with B/C/D Tripping Curve
TMA3-40 1P+N Circuit Breaker with B/C/D Tripping Curve
TMA3-40 1P+N Circuit Breaker with B/C/D Tripping Curve
TMA3-40 1P+N Circuit Breaker with B/C/D Tripping Curve
TMA3-40 1P+N Circuit Breaker with B/C/D Tripping Curve

 

Packaging & Shipping

White gift box option: Carefully packages each unit in a premium gift box, ideal for exclusive presentations.

TMA3-40 1P+N Circuit Breaker with B/C/D Tripping Curve
TMA3-40 1P+N Circuit Breaker with B/C/D Tripping Curve
TMA3-40 1P+N Circuit Breaker with B/C/D Tripping Curve


Yellow carton box option: Efficiently accommodates 60 units per carton, perfectly suited for bulk distribution.

TMA3-40 1P+N Circuit Breaker with B/C/D Tripping Curve
In distribution, Timelec offers a strong, durable corrugated carton box:
Timelec's corrugated carton box signifies robustness with:

Superior quality,
Outstanding edge crush resistance,
Discreet, sophisticated black print.

 

Installation Instructions

TMA3-40 1P+N Circuit Breaker with B/C/D Tripping Curve

Company Profile

TMA3-40 1P+N Circuit Breaker with B/C/D Tripping CurveTMA3-40 1P+N Circuit Breaker with B/C/D Tripping CurveTMA3-40 1P+N Circuit Breaker with B/C/D Tripping CurveTMA3-40 1P+N Circuit Breaker with B/C/D Tripping Curve

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier