IEC/EN 62606 Standard Afdd 1P+N Circuit Breaker with B/C/D Curve

Product Details
Customization: Available
Breaking Capacity: Low Voltage Circuit Breakers
Operation: Electric Type
Still deciding? Get samples of $ !
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW PayPal
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company

360° Virtual Tour

Industry-leading Audited Factory

Secured Trading Service
Diamond Member Since 2015

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
to see all verified strength labels (22)
  • IEC/EN 62606 Standard Afdd 1P+N Circuit Breaker with B/C/D Curve
  • IEC/EN 62606 Standard Afdd 1P+N Circuit Breaker with B/C/D Curve
  • IEC/EN 62606 Standard Afdd 1P+N Circuit Breaker with B/C/D Curve
  • IEC/EN 62606 Standard Afdd 1P+N Circuit Breaker with B/C/D Curve
  • IEC/EN 62606 Standard Afdd 1P+N Circuit Breaker with B/C/D Curve
  • IEC/EN 62606 Standard Afdd 1P+N Circuit Breaker with B/C/D Curve
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • FAQ
  • Our Advantages
  • Certifications
  • Packaging & Shipping
  • Installation Instructions
  • Company Profile
Overview

Basic Info.

Model NO.
TMA1-40 1P+N 6kA C40 TypeAC
Speed
High-Speed Circuit Breaker
Arc-extinguishing Medium
Air
Installation
Fixed
Structure
AFDD
Poles Number
1P+N
Type
Circuit Breaker
Function
Overcurrent Protection, RCCB
Certification
VDE, ISO9001-2000, CE, CB, Ukca, NF
Standard
IEC/En 62606 & IEC 61009-1
Pole
1P+N
Tripping Curve
B, C, D
Rated Current (in)
6A, 10A, 16A, 20A, 25A, 32A, 40A
Residual Current Type
Type A, AC
Residual Current (LΔn)
30mA, 100mA, 300mA
Making Breaking Capacity (IΔm)
2, 000A
Icn
6kA
Energy Limiting Class
3
keywords
afdd and rcd
keywords2
afdd circuit breaker
keywords3
arc detection device
Transport Package
White Gift Box, Yellow Carton Box
Specification
115 x 69.6 x 18 mm
Trademark
Timelec, OEM / Private Label brands
Origin
China
HS Code
8536200000
Production Capacity
200, 000

Packaging & Delivery

Package Size
9.00cm * 3.30cm * 1.20cm
Package Gross Weight
0.200kg

Product Description

Product Description

Introducing the AFDD, also known by its full form as the Arc-Fault Detection Device, and known in North America as the Arc Fault Circuit Interrupter (AFCI). This state-of-the-art device is meticulously crafted to adhere to the rigorous IEC/BS EN 62606 standards, promising unmatched safety and reliability for users. Experience peace of mind, knowing your electrical systems are protected by a device designed with precision and care.
In the realm of circuit protection, Timelec stands as a beacon of excellence, offering an unmatched suite of protective devices. Our Miniature Circuit Breakers (MCBs) are expertly crafted for superior short-circuit and overload protection. Complementing these, our Residual Current Devices (RCDs or RCCBs) deliver formidable residual current protection. Yet, with an astonishing 90% of electrical fires being sparked by electric arcs, traditional methods simply fall short. Enter the AFDD, an indispensable guardian offering critical arc protection, crafted to shield both lives and properties with unparalleled efficacy.

 

The Timelec AFDD is truly a marvel, an integrated solution merging the functionalities of both AFDD and RCBO. This device offers a comprehensive shield against short-circuits, overloads, residual currents, arcs, and over-voltages, all while adhering to the stringent IEC/BS EN 62606 and IEC/BS EN 61009-1 standards. With intelligent technology, it distinguishes between benign and perilous arcs, promptly interrupting the circuit when detecting an arc-a common result of loose connections. This proactive measure is especially crucial in older home wiring, where such arcs can escalate into devastating fires.

Product Parameters
Product category CIRCUIT BREAKER
Product type ARC FAULT DETECTION DEVICES (AFDDs)
Product model TMA3-40
Unique selling
proposition
With AFD+RCBO protection
With Over-vol. protection
Total length, 115mm
Technical data   Standard IEC/EN 62606 & IEC 61009-1
Electrical features Rated curret (In) 6A,10A,16A,20A,25A,32A,40A
Trip curve B, C, D
Model Electronic
RCD Type AC, A
Pole 1P+N
Rate voltage (Ue) 240V
Insulation voltage(Ui) 500V
Rated frequency 50Hz
Energy limiting class 3
Rated residual operating current (IΔn) 30mA, 100mA, 300mA
Rated breaking capacity (Icn) 6KA
Rated operating short circuit breaking capacity (Ics) 6KA
Rated residual making and breaking capacity(IΔm) 2000A
Rated impulse withstand voltage (Uimp) 4KV
Surge current resistance / at (8/20) μs 3KA
Overvoltage protection 270V-300V
Electrical life 4,000
Pollution degree 2
Mechanical features Mechanical life 20,000
Protection degree IP20
Ambient temperature (with daily averages35°C) -25°C +40°C
Storage temperature -25°C +70°C
Installation Terminal connection type Cable, busbar
Connection capacity (input) 25mm2
Connection capacity (output) 16mm2
Tightening torque (input) 2.5Nm
Tightening torque (output) 1.2Nm
35mm DIN rail
IEC/EN 62606 Standard Afdd 1P+N Circuit Breaker with B/C/D Curve
FAQ
Whatarearcs?
Visible plasma discharges caused by electrical current passing through a normally nonconductive medium, such as air.
It is caused when the electrical current ionizes gases in the air.
The temperature can exceed 600 ºC, sufficient to start a fire.
(20% fire associated with electrical distribution or other electrical appliance faults.)
IEC/EN 62606 Standard Afdd 1P+N Circuit Breaker with B/C/D Curve
Whatcauses arcs?
An arc is created when the electrical current jumps between two conductive material. Most 2 types of arcs are Serial
Arc and Parallel Arc.

Most common causes includes:
1. worn contacts in electrical equipment,
2. damage to insulation,
3. break in cable and loose connections, Etc.
IEC/EN 62606 Standard Afdd 1P+N Circuit Breaker with B/C/D Curve


What is AFDD?
AFDD is protective device installed in consumer units to provide protection from arc faults.
It uses microprocessor technology to analyze the waveform of the electricity being used to detect any unusual signatures
which would signify an arc on the circuit.

It will cut off the power to the affected circuit and could prevent a fire.
IEC/EN 62606 Standard Afdd 1P+N Circuit Breaker with B/C/D Curve
Do I need to install AFDD?
Yes, it is highly recommended where there is an increased risk of fire
IEC/EN 62606 Standard Afdd 1P+N Circuit Breaker with B/C/D CurveIEC/EN 62606 Standard Afdd 1P+N Circuit Breaker with B/C/D Curve
According to IEC 60364 - Electrical installations of buildings Part 4-42 :
Arc Fault Detection Devices are designed to limit fire risks caused by the presence of arc fault currents in the final circuits of a fixed installation.They are installed in electrical switchboards, to protect circuits supplying power sockets and lighting and are especially recommended in cases of renovation.


More specifically, the installation of the AFDD is highly recommended to protect circuits with highest risk of fire, such as:
Protruding cables (risk of knocks)
Outside cables (greater risk of deterioration)
Unprotected cables in secluded areas (like storage rooms)
Aging, deteriorating wiring or wiring for which the connection boxes are inaccessible.
Our Advantages

The Timelec AFDD (AFCI) impresses with its compact and streamlined design, measuring just 115mm in total length. This space-efficient marvel fits seamlessly into various installations without compromising on robust protection.
Despite its sleek and compact structure, the Timelec AFDD delivers unwavering protection and exemplary performance, ensuring reliability and security in every application.

For those seeking the pinnacle of protection, Timelec AFDD is the ultimate choice, offering comprehensive coverage in both domestic and commercial settings. Its unparalleled performance grants users the priceless gift of peace of mind.

Timelec offers a wide array of customization options to meet diverse client needs:

Expect sophisticated printing options, including laser and pad methods, allowing for detailed and precise branding for your products.
Choose from stately white gift boxes for select product packaging, elevating the perceived value and presentation.
For bulk packaging, durable yellow carton boxes are available, ensuring robustness and practicality across our entire product range.
Our innovative product design services stand ready, offering new molds based on volume, allowing for tailored product creation to meet your specific needs.
 
Certifications
IEC/EN 62606 Standard Afdd 1P+N Circuit Breaker with B/C/D Curve
IEC/EN 62606 Standard Afdd 1P+N Circuit Breaker with B/C/D Curve
IEC/EN 62606 Standard Afdd 1P+N Circuit Breaker with B/C/D Curve
IEC/EN 62606 Standard Afdd 1P+N Circuit Breaker with B/C/D Curve
IEC/EN 62606 Standard Afdd 1P+N Circuit Breaker with B/C/D Curve
IEC/EN 62606 Standard Afdd 1P+N Circuit Breaker with B/C/D Curve

 

Packaging & Shipping

Each individual product is gracefully enclosed in a pristine white gift box, with one piece per box, showcasing elegance and care.

IEC/EN 62606 Standard Afdd 1P+N Circuit Breaker with B/C/D Curve
IEC/EN 62606 Standard Afdd 1P+N Circuit Breaker with B/C/D Curve
IEC/EN 62606 Standard Afdd 1P+N Circuit Breaker with B/C/D Curve


For larger orders, our sturdy yellow carton box accommodates an efficient 60 pieces per carton, optimizing both storage and transportation.

IEC/EN 62606 Standard Afdd 1P+N Circuit Breaker with B/C/D Curve
Throughout our distribution network, we uphold packaging security by employing:
Timelec's robust corrugated carton boxes, which feature:

High-quality, resilient materials,
Remarkable edge crush resistance for added protection,
Neutral yet sophisticated black print for a touch of elegance.

 

Installation Instructions

IEC/EN 62606 Standard Afdd 1P+N Circuit Breaker with B/C/D Curve

Company Profile

IEC/EN 62606 Standard Afdd 1P+N Circuit Breaker with B/C/D CurveIEC/EN 62606 Standard Afdd 1P+N Circuit Breaker with B/C/D CurveIEC/EN 62606 Standard Afdd 1P+N Circuit Breaker with B/C/D CurveIEC/EN 62606 Standard Afdd 1P+N Circuit Breaker with B/C/D Curve

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier