SPD Surge Protective Devices are engineered to offer robust defense against transient surge conditions. Major surge events, like lightning strikes, can unleash voltages in the hundreds of thousands, leading to immediate or sporadic equipment malfunctions. However, lightning and utility power irregularities contribute to only 20% of these transient surges. The overwhelming 80% originate internally. While these internal surges may be lower in magnitude, their frequent nature can gradually erode the performance of sensitive electronic devices within a facility.
A power surge represents a short-lived overvoltage episode capable of inflicting damage to electrical devices, often resulting in equipment failure. Surges have the potential to harm and diminish the longevity of:
NEW 2020 National Electrical Code Requirements
All newly constructed and renovated homes must be equipped with Listed and Approved Type 1 or Type 2 Surge Protective Devices, ensuring comprehensive protection.
Type 1:
A permanently connected Surge Protective Device, safeguarding against both external and internal surges. It is versatile enough for installation inside or outside residential premises.
Type 2:
A permanently connected Surge Protective Device installed in proximity to a breaker box. It provides reliable protection against internal and external surges.
Type 3:
Offers additional protection. It is a point-of-use Surge Protective Device and must work alongside Type 1 or Type 2 SPDs to comply with the 2020 code requirements.
For the most comprehensive protection, deploy Type 1, 2, and 3 SPDs together to ensure the highest level of safety.
Max Continuous Operating Voltage | Ucpv | 500VDC | 600VDC | 1000VDC | 1500VDC | ||||||
Nominal Discharge Current | In | 20kA | 20kA | 20kA | 20kA | ||||||
Max Discharge Current | lmax | 40kA | 40 kA | 40kA | 40kA | ||||||
Protection level | Up | 2.8kV | 3.0kV | 3.5kV | 5.5 kV | ||||||
Rated shortcircuit current | IscCI | 100A | |||||||||
lcpv | 0.2 mA | ||||||||||
Connection mode | paralle | ||||||||||
Response Time | tA | 25ns | |||||||||
Back up fuse | LT-SSD40 | ||||||||||
Remotecommunication | With | ||||||||||
Remote communication connection | 1411:NO,1112:NC | ||||||||||
Remote contact rated current | 220V/0.5A | ||||||||||
Associateddisconnectors | |||||||||||
Thermal disconnector | internal | ||||||||||
Fuses | Fuses type gG100A | ||||||||||
ground fault breaker | None | ||||||||||
Mechnicalcharacteristics | |||||||||||
Connection | By screw terminals:6-35mm | ||||||||||
Terminal Screw Torque | 2.5 Nm | ||||||||||
RecommendedCable cross Section | ≥16mm² | ||||||||||
Insertwire length | 15mm | ||||||||||
Mounting | DIN rail 35mm (EN60715) | ||||||||||
Degree of Protection | IP20 | ||||||||||
Housing | PBT | ||||||||||
Flame retardant grade | UL94 V0 | ||||||||||
Operating temperature | -40ºC~+70ºC | ||||||||||
Operatingrelative humidity | 5%-95% | ||||||||||
Working atmospheric pressure | 70kPa~106kPa | ||||||||||
Connection | By screw terminals:6-35mm |
Selection of SPD:
For a power distribution system, choosing the right SPD is crucial. Key characteristics that define the lightning protection system and guide the selection of an SPD for safeguarding an electrical installation in a building include:
Other predefined characteristics for selecting an SPD within an electrical installation include:
This sub-section Design of the electrical installation protection system provides an in-depth analysis of the criteria for selecting a protection system. It takes into account installation characteristics, equipment specifics, and environmental factors.
Location and types of SPD:
Connection of SPD:
Connections of an SPD to the loads should be kept as short as possible to minimize the voltage protection level (installed Up) on the terminals of the protected equipment.
Ensure that the total length of SPD connections to the network and to the earth terminal block remains under 50 cm.
SPD in plastic enclosure SPD in metal enclosure
RED: Replace