Discover the remarkable RCBO, the Residual-current Circuit Breaker with Overcurrent protection, or commonly known as GFCI, Ground Fault Circuit Interrupter. Proudly adhering to the distinguished standards of IEC/BS EN 61009-1 and GB16917, this exceptional circuit breaker merges the impressive functionalities of both MCB and RCD (RCCB). With Timelec RCBO, you are assured comprehensive protection against overloads, short-circuits, and residual currents. Our RCBOs are tailored into two distinct types, each defined by their tripping mechanism, namely ELE (ELEctronic) and ELM (ELectroMagnetic). Additionally, our range expands into four primary types categorized by the waveform and frequency of fault current, including Type Ac, Type A, Type F, and Type B. These are meticulously selected as per the national standards across different countries, ensuring unparalleled reliability and compliance.
Product category | CIRCUIT BREAKER | ||
Product type | Residual current operated circuit-breakers with integral overcurrent protection (RCBO) | ||
Product model | TMRO10-63 | ||
Business information |
MOQ: 120pcs Payment: T/T, L/C Delivery time: 15-60 days Loading Port: Ningbo or Shanghai, China Certification: ISO9001:2015 Logo: pad printing, laser printing (customized design are acceptable) |
||
Unique selling proposition | Prevention from overloading and short-circuit currents, Detection of the earth leakage current. Protection against indirect contacts and direct contacts. Preventing fire hazard in cause of circuit fault. Widly used in residual building and other recombiner distribution boxes |
||
Technical data | Standard | IEC 61009-1, GB16917.1 | |
Electrical features | Rated current (In) | 6A, 10A, 16A, 20A,25A, 32A, 40A, 50A, 63A | |
Trip curve | B, C, D | ||
Model | Electronic/Electromagnetic | ||
RCD Type | AC, A | ||
Pole | 2P, 4P | ||
Rate voltage (Ue) | 240V/415V | ||
Insulation voltage(Ui) | 500V | ||
Rated frequency | 50/60Hz | ||
Energy limiting class | 3 | ||
Rated residual operating current (IΔn) | 30mA, 100mA, 300mA | ||
Rated breaking capacity (Icn) | 6KA/10KA | ||
Rated operating short circuit breaking capacity (Ics) | 6KA/7.5KA | ||
Rated residual making and breaking capacity(IΔm) | 3000A | ||
Rated impulse withstand voltage (Uimp) | 4KV | ||
Surge current resistance / at (8/20) μs | 3KA | ||
Electrical life | 4,000 | ||
Pollution degree | 2 | ||
Mechanical features | Mechanical life | 20,000 | |
Protection degree | IP20 | ||
Ambient temperature (with daily averages35°C) | -25°C +40°C | ||
Storage temperature | -25°C +70°C | ||
Installation | Terminal connection type | Cable, busbar | |
Connection capacity (input) | 25mm2 | ||
Connection capacity (output) | 25mm2 | ||
Tightening torque (input) | 2.5Nm | ||
Tightening torque (output) | 2.5Nm | ||
35mm DIN rail |