Residential AC Surge Protective Device, 230V, 20kA In, 40kA Imax device

Product Details
Customization: Available
Type: Power Source Arrester
Structure: Valve Type Arrester
Still deciding? Get samples of $ !
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW PayPal
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company

360° Virtual Tour

Industry-leading Audited Factory

Secured Trading Service
Diamond Member Since 2015

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
to see all verified strength labels (22)
  • Residential AC Surge Protective Device, 230V, 20kA In, 40kA Imax device
  • Residential AC Surge Protective Device, 230V, 20kA In, 40kA Imax device
  • Residential AC Surge Protective Device, 230V, 20kA In, 40kA Imax device
  • Residential AC Surge Protective Device, 230V, 20kA In, 40kA Imax device
  • Residential AC Surge Protective Device, 230V, 20kA In, 40kA Imax device
  • Residential AC Surge Protective Device, 230V, 20kA In, 40kA Imax device
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Installation Instructions
Overview

Basic Info.

Model NO.
TMSPD1
Installation
Parallel Arrester
Application
AC/DC System
Size
Small
Operation Voltage
Low Voltage
Shape
Cuboid
Material
ZnO
Certification
ISO9001
Brand
Timelec
Uc
230V
In
20kA
Imax
40kA
Up
1.5kV
IEC
IEC61643-11
IP
IP20
Protection
Class II, T2
Transport Package
Carton Box
Specification
36*69*91mm
Trademark
Timelec, OEM / Private Label brands
Origin
China
HS Code
853620
Production Capacity
1000000

Packaging & Delivery

Package Size
4.00cm * 9.30cm * 7.50cm
Package Gross Weight
0.300kg

Product Description

Product Description

Our Surge Protective Devices (SPDs) serve as formidable guardians against the unpredictable threats of transient surge conditions. These devices are engineered to withstand and mitigate the devastating impact of large, singular surge events such as lightning strikes, which can unleash voltage spikes reaching hundreds of thousands of volts, causing immediate or sporadic equipment failure. However, it's crucial to note that only 20% of transient surges arise from external sources like lightning or utility power anomalies. A staggering 80% are generated internally within the facility. Despite their smaller magnitude, these frequent surges pose a significant risk by gradually degrading sensitive electronic equipment over time. With continuous exposure, even these less intense surges can lead to malfunction or reduce the lifespan of your vital electronic assets.

Key Product Features
1. Comprehensive 1P+N phase protection designed for both AC and DC systems, ensuring robust defense.

2. User-friendly pluggable module design facilitates effortless installation and maintenance, saving you time and effort.

3. Superior discharge capacity with an ultra-quick response time, providing formidable protection against surges.

4. Equipped with dual thermal disconnection devices, this ensures enhanced reliability and safety.

5. An innovative green indicator window alerts you to faults and simultaneously provides remote alarm control, enhancing security and awareness.


A power surge, characterized by a brief overvoltage event, poses a significant threat to electrical devices, often leading to equipment failure. These surges can inflict damage and reduce the operational lifespan of:

  • Heating and Air Conditioning Systems, which are vital for maintaining comfort and air quality.
  • Washers and Dryers, essential for household convenience and hygiene.
  • Water Heaters, crucial for ensuring a steady supply of hot water.
  • Ranges & Refrigerators, which are the backbone of kitchen functionality.
  • Lighting systems, integral for both practical and aesthetic purposes.
  • Entertainment Systems, providing leisure and relaxation at home.

According to the National Electrical Manufacturers Association, the average home harbors approximately $15,000 worth of equipment that is vulnerable to surge damage.

Primary Causes of Power Surges:
Research shows that a significant 80% of power surges originate from internal sources.

Internal Sources Include:

  • The operation of large appliances, which can cause fluctuations when turning on or off.
  • Faulty wiring or loose connections, which pose a hidden but serious risk.
  • Overloaded circuits, short circuits, or ground faults, all of which can trigger unexpected surges.
  • Power recovery processes, which can inadvertently generate surges.

External Sources Include:

  • Lightning strikes, notorious for their destructive surge impact.
  • Damage to power lines, which can disrupt the flow and create surges.
  • Utility power grid switching, a common external cause of surges.


NEW 2020 National Electrical Code Requirements
All new and renovated residential properties must now be safeguarded by Listed and Approved Type 1 or Type 2 Surge Protective Devices, ensuring comprehensive surge protection.

Type 1 SPDs:
These are permanently connected Surge Protective Devices that guard against both external and internal surges. They can be installed either inside or outside the home, offering flexible protection options.

Type 2 SPDs:
Also permanently connected, these devices are installed in or adjacent to breaker boxes, providing robust protection against both internal and external surges.

Type 3 SPDs:
These offer additional, point-of-use protection and must be used in conjunction with Type 1 or Type 2 SPDs to comply with the 2020 code requirements, ensuring optimal safety and device longevity.

For the utmost protection, it is recommended to use a combination of Type 1, 2, and 3 SPDs, providing a comprehensive defense against all potential surge threats.

Product Parameters
Product category Surge protection
Product type SURGE PROTECTIVE DEVICE
Product model HLSPD,SPD,TMSPD2
Unique selling proposition ·TMSPD1 SPD are suit for IT,TT,TN-C,TN-S,TN-C-S and low-voltage AC power distribution system, protect both direct and indirect lighting impulse and other transient over voltage.
·TMSPD1 surge protection device have high energy MOV chip, fast response speed.
·Products comply with IEC61643-1.2005, IEC61643-11.2011 standard.
Technical data Type of SPD according to EN 61643-11 Type 2
SPD according to IEC 61643-1 Class II
Nominal a.c voltage( Un) 230V
Max continuous operating a.c voltage (Uc) 275/320/385/440V
Nominal discharge current (In 8/20|jS) 10/20KA
Max. discharge current (Imax 8/20pS) 20/40KA
Voltage protection level (Up) <1.3/1.4/1.5/1.8/2.2KV
Response time (tA) <25ns
Operating temperature range (Tu) -40°C +80°C
Operating state/fault indication Green/red
Cross-section area (min) 4mm²
Cross-section area (Max) 16mm²
For mounting on 35mm DIN rail acc to EN60715
Degree of protection IP20
Terminal screw torque 2.5N·m
Approvals TUV
 
Installation Instructions

Selection of SPD:
To safeguard your building's electrical installations, selecting the right SPD is crucial. Consider the power distribution system's characteristics which define the lightning protection system. By understanding these attributes, you ensure optimal protection with a suitable SPD.

  • SPD
    • quantity of SPD
    • type
    • Assess the level of exposure to determine the SPD's maximum discharge current, known as Imax. This defines the SPD's ability to handle high-energy surges effectively.
  • Short circuit protection device
    • maximum discharge current Imax;
    • Consider the short-circuit current Isc at the installation point to ensure robust protection and compatibility.
Residential AC Surge Protective Device, 230V, 20kA In, 40kA Imax device

Other selection criteria for an SPD are standardized for any given electrical installation for consistency and safety.

  • number of poles in SPD;
  • voltage protection level Up;
  • operating voltage Uc.

This sub-section Design of the electrical installation protection system delves into detailed criteria tailored to your installation's unique characteristics, the equipment it protects, and the surrounding environment to ensure comprehensive protection.

Location and types of SPD:
Residential AC Surge Protective Device, 230V, 20kA In, 40kA Imax device

Connection of SPD:
Ensure SPD connections to loads are as brief as possible. This minimizes the voltage protection level (installed Up) at the equipment's terminals, enhancing protection.

Keep the total SPD connection length to the network and earth terminal within 50 cm to maintain efficacy and safety.

Residential AC Surge Protective Device, 230V, 20kA In, 40kA Imax device
Residential AC Surge Protective Device, 230V, 20kA In, 40kA Imax device

SPD in plastic enclosure SPD in metal enclosure

Residential AC Surge Protective Device, 230V, 20kA In, 40kA Imax device
Residential AC Surge Protective Device, 230V, 20kA In, 40kA Imax device

 

RED: Replace
Should the indicator display RED, it's imperative to replace the product to maintain optimal protection and safety.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier