Reliable Afdd Circuit Breaker 1P+N Standard IEC/EN 62606 B/C/D

Product Details
Customization: Available
Breaking Capacity: Low Voltage Circuit Breakers
Operation: Electric Type
Still deciding? Get samples of $ !
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW PayPal
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company

360° Virtual Tour

Industry-leading Audited Factory

Secured Trading Service
Diamond Member Since 2015

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
to see all verified strength labels (22)
  • Reliable Afdd Circuit Breaker 1P+N Standard IEC/EN 62606 B/C/D
  • Reliable Afdd Circuit Breaker 1P+N Standard IEC/EN 62606 B/C/D
  • Reliable Afdd Circuit Breaker 1P+N Standard IEC/EN 62606 B/C/D
  • Reliable Afdd Circuit Breaker 1P+N Standard IEC/EN 62606 B/C/D
  • Reliable Afdd Circuit Breaker 1P+N Standard IEC/EN 62606 B/C/D
  • Reliable Afdd Circuit Breaker 1P+N Standard IEC/EN 62606 B/C/D
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • FAQ
  • Our Advantages
  • Certifications
  • Packaging & Shipping
  • Installation Instructions
  • Company Profile
Overview

Basic Info.

Model NO.
TMA1-40 1P+N 6kA C40 TypeAC
Speed
High-Speed Circuit Breaker
Arc-extinguishing Medium
Air
Installation
Fixed
Structure
AFDD
Poles Number
1P+N
Type
Circuit Breaker
Function
Overcurrent Protection, RCCB
Certification
VDE, ISO9001-2000, CE, CB, Ukca, NF
Standard
IEC/En 62606 & IEC 61009-1
Pole
1P+N
Tripping Curve
B, C, D
Rated Current (in)
6A, 10A, 16A, 20A, 25A, 32A, 40A
Residual Current Type
Type A, AC
Residual Current (LΔn)
30mA, 100mA, 300mA
Making Breaking Capacity (IΔm)
2, 000A
Icn
6kA
Energy Limiting Class
3
keywords
afdd and rcd
keywords2
afdd circuit breaker
keywords3
arc detection device
Transport Package
White Gift Box, Yellow Carton Box
Specification
115 x 69.6 x 18 mm
Trademark
Timelec, OEM / Private Label brands
Origin
China
HS Code
8536200000
Production Capacity
200, 000

Packaging & Delivery

Package Size
9.00cm * 3.30cm * 1.20cm
Package Gross Weight
0.200kg

Product Description

Product Description

Introducing the AFDD, known globally as the Arc-Fault Detection Device and in North America as the AFCI (Arc Fault Circuit Interrupter). This device is crafted with meticulous precision to meet IEC/BS EN 62606 standards, promising unmatched safety and reliability for your peace of mind.
In the realm of circuit protection, Timelec is synonymous with excellence, showcasing an impressive array of protective devices. Our MCBs are meticulously engineered for unparalleled short-circuit and overload protection, while our RCDs (RCCB) stand out with their formidable residual current protection capabilities. Yet, as astonishing as it sounds, 90% of electrical fires stem from electric arcs. This is where our AFDD shines, providing essential arc protection to safeguard both lives and properties.

 

The Timelec AFDD is a groundbreaking all-in-one solution, seamlessly integrating AFDD and RCBO functionalities. It delivers exceptional short-circuit, overload, residual current, arc, and over-voltage protection, all while adhering to the rigorous IEC/BS EN 62606 and IEC/BS EN 61009-1 standards. Our innovative device skillfully distinguishes between benign and hazardous arcs, promptly interrupting the circuit to prevent potential fires, particularly in aging home wiring where loose connections are common.

Product Parameters
Product category CIRCUIT BREAKER
Product type ARC FAULT DETECTION DEVICES (AFDDs)
Product model TMA3-40
Unique selling
proposition
With AFD+RCBO protection
With Over-vol. protection
Total length, 115mm
Technical data   Standard IEC/EN 62606 & IEC 61009-1
Electrical features Rated curret (In) 6A,10A,16A,20A,25A,32A,40A
Trip curve B, C, D
Model Electronic
RCD Type AC, A
Pole 1P+N
Rate voltage (Ue) 240V
Insulation voltage(Ui) 500V
Rated frequency 50Hz
Energy limiting class 3
Rated residual operating current (IΔn) 30mA, 100mA, 300mA
Rated breaking capacity (Icn) 6KA
Rated operating short circuit breaking capacity (Ics) 6KA
Rated residual making and breaking capacity(IΔm) 2000A
Rated impulse withstand voltage (Uimp) 4KV
Surge current resistance / at (8/20) μs 3KA
Overvoltage protection 270V-300V
Electrical life 4,000
Pollution degree 2
Mechanical features Mechanical life 20,000
Protection degree IP20
Ambient temperature (with daily averages35°C) -25°C +40°C
Storage temperature -25°C +70°C
Installation Terminal connection type Cable, busbar
Connection capacity (input) 25mm2
Connection capacity (output) 16mm2
Tightening torque (input) 2.5Nm
Tightening torque (output) 1.2Nm
35mm DIN rail
Reliable Afdd Circuit Breaker 1P+N Standard IEC/EN 62606 B/C/D
FAQ
Whatarearcs?
Visible plasma discharges caused by electrical current passing through a normally nonconductive medium, such as air.
It is caused when the electrical current ionizes gases in the air.
The temperature can exceed 600 ºC, sufficient to start a fire.
(20% fire associated with electrical distribution or other electrical appliance faults.)
Reliable Afdd Circuit Breaker 1P+N Standard IEC/EN 62606 B/C/D
Whatcauses arcs?
An arc is created when the electrical current jumps between two conductive material. Most 2 types of arcs are Serial
Arc and Parallel Arc.

Most common causes includes:
1. worn contacts in electrical equipment,
2. damage to insulation,
3. break in cable and loose connections, Etc.
Reliable Afdd Circuit Breaker 1P+N Standard IEC/EN 62606 B/C/D


What is AFDD?
AFDD is protective device installed in consumer units to provide protection from arc faults.
It uses microprocessor technology to analyze the waveform of the electricity being used to detect any unusual signatures
which would signify an arc on the circuit.

It will cut off the power to the affected circuit and could prevent a fire.
Reliable Afdd Circuit Breaker 1P+N Standard IEC/EN 62606 B/C/D
Do I need to install AFDD?
Yes, it is highly recommended where there is an increased risk of fire
Reliable Afdd Circuit Breaker 1P+N Standard IEC/EN 62606 B/C/DReliable Afdd Circuit Breaker 1P+N Standard IEC/EN 62606 B/C/D
According to IEC 60364 - Electrical installations of buildings Part 4-42 :
Arc Fault Detection Devices are designed to limit fire risks caused by the presence of arc fault currents in the final circuits of a fixed installation.They are installed in electrical switchboards, to protect circuits supplying power sockets and lighting and are especially recommended in cases of renovation.


More specifically, the installation of the AFDD is highly recommended to protect circuits with highest risk of fire, such as:
Protruding cables (risk of knocks)
Outside cables (greater risk of deterioration)
Unprotected cables in secluded areas (like storage rooms)
Aging, deteriorating wiring or wiring for which the connection boxes are inaccessible.
Our Advantages

The Timelec AFDD (AFCI) is designed with a sleek and compact form factor, boasting a total length of just 115mm.
Despite its diminutive size, it offers an unparalleled level of protection and performance, ensuring your safety is never compromised.

Timelec AFDD stands as the top-tier choice for comprehensive protection, whether in domestic or commercial settings, delivering unmatched peace of mind.

Timelec offers extensive customization options to cater to your unique needs:

Branding can be elegantly achieved through precise laser or pad printing options.
Packaging is available in sophisticated white gift boxes for select products, enhancing their perceived value and appeal.
For bulk packaging, we offer robust yellow carton boxes across our entire product range.
Our innovative product design services include the creation of new molds based on order volume, ensuring your products stand out.
 
Certifications
Reliable Afdd Circuit Breaker 1P+N Standard IEC/EN 62606 B/C/D
Reliable Afdd Circuit Breaker 1P+N Standard IEC/EN 62606 B/C/D
Reliable Afdd Circuit Breaker 1P+N Standard IEC/EN 62606 B/C/D
Reliable Afdd Circuit Breaker 1P+N Standard IEC/EN 62606 B/C/D
Reliable Afdd Circuit Breaker 1P+N Standard IEC/EN 62606 B/C/D
Reliable Afdd Circuit Breaker 1P+N Standard IEC/EN 62606 B/C/D

 

Packaging & Shipping

Each product is elegantly presented in a white gift box, with one unit per box, making for a refined presentation.

Reliable Afdd Circuit Breaker 1P+N Standard IEC/EN 62606 B/C/D
Reliable Afdd Circuit Breaker 1P+N Standard IEC/EN 62606 B/C/D
Reliable Afdd Circuit Breaker 1P+N Standard IEC/EN 62606 B/C/D


For bulk orders, our sturdy yellow carton box efficiently holds 60 units per carton, optimizing both storage and transport.

Reliable Afdd Circuit Breaker 1P+N Standard IEC/EN 62606 B/C/D
Our distribution network guarantees secure packaging with:
Timelec's durable corrugated carton boxes, featuring:

Premium quality materials for enhanced protection,
Exceptional edge crush resistance to withstand tough conditions,
A neutral and sophisticated black print for a professional appearance.

 

Installation Instructions

Reliable Afdd Circuit Breaker 1P+N Standard IEC/EN 62606 B/C/D

Company Profile

Reliable Afdd Circuit Breaker 1P+N Standard IEC/EN 62606 B/C/DReliable Afdd Circuit Breaker 1P+N Standard IEC/EN 62606 B/C/DReliable Afdd Circuit Breaker 1P+N Standard IEC/EN 62606 B/C/DReliable Afdd Circuit Breaker 1P+N Standard IEC/EN 62606 B/C/D

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier