Versatile DC Surge Protector 275V 255V, 20kA In, 40kA Imax

Product Details
Customization: Available
Type: Power Source Arrester
Structure: Zinc Oxide Arrester
Still deciding? Get samples of $ !
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company

360° Virtual Tour

Industry-leading Audited Factory

Secured Trading Service
Diamond Member Since 2015

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
to see all verified strength labels (22)
  • Versatile DC Surge Protector 275V 255V, 20kA In, 40kA Imax
  • Versatile DC Surge Protector 275V 255V, 20kA In, 40kA Imax
  • Versatile DC Surge Protector 275V 255V, 20kA In, 40kA Imax
  • Versatile DC Surge Protector 275V 255V, 20kA In, 40kA Imax
  • Versatile DC Surge Protector 275V 255V, 20kA In, 40kA Imax
  • Versatile DC Surge Protector 275V 255V, 20kA In, 40kA Imax
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Installation Instructions
Overview

Basic Info.

Model NO.
TMSPD7
Installation
Tandem Arrester
Application
AC/DC System
Size
Small
Operation Voltage
Low Voltage
Shape
Cuboid
Material
PBT Fireproof
Certification
ROHS, ISO9001, CE
Brand
Timelec
Uc
275V / 255V
In
20kA
Imax
40kA
Up
1.5kV
IEC
IEC61643-11
IP
IP20
Protection
Class II, T2
Transport Package
Carton Box
Specification
18mm
Trademark
Timelec, OEM / Private Label brands
Origin
China
HS Code
853620
Production Capacity
1000000

Packaging & Delivery

Package Size
4.60cm * 7.80cm * 3.60cm
Package Gross Weight
0.190kg

Product Description

Product Description

Introducing Taimu Electrical's SPD Surge Protective Devices: the unrivaled protectors of your electronic sanctum, meticulously engineered to defend against the capricious onslaught of voltage surges. Imagine the formidable force of a lightning strike, unleashing a torrent of hundreds of thousands of volts, threatening to compromise your critical equipment. While such dramatic events account for a mere 20% of surges, the true menace lies within-the stealthy, internal surges constituting a massive 80%. Though less dramatic than a lightning strike, their relentless occurrence can subtly but surely degrade sensitive electronics within your premises.


Power surges, those ephemeral voltage overloads, pose a serious threat that can lead to the premature failure of your cherished electrical devices. The impact of these surges reverberates through an array of household staples, inevitably curtailing their longevity and efficiency:

  • Heating and Air Conditioning Systems
  • Washers and Dryers
  • Water Heaters
  • Ranges & Refrigerators
  • Lighting
  • Entertainment Systems

NEW 2020 National Electrical Code Requirements
In accordance with the landmark 2020 National Electrical Code, every new and retrofitted home must be equipped with Listed and Approved Type 1 or Type 2 Surge Protective Devices, establishing an elevated benchmark of security.

Type 1:
A robust, permanently connected Surge Protective Device that serves as a formidable defender against both external and internal voltage surges. Its versatile installation allows it to be placed either within or outside your home, providing flexible protective options.

Type 2:
A vigorous, permanently connected Surge Protective Device, strategically installed near or within the breaker box to effectively combat both internal and external surges, ensuring comprehensive coverage.

Type 3:
Offering supreme protection, this point-of-use Surge Protective Device delivers an added shield when used alongside Type 1 or Type 2 SPDs, aligning perfectly with the 2020 code standards for optimal defense.

For the ultimate in electrical safety, deploy a strategic blend of Type 1, 2, and 3 Surge Protective Devices, ensuring your home stands impregnable against any electrical disturbances.

Product Parameters
Max Continuous Operating Voltage Ucpv 500VDC 600VDC 1000VDC 1500VDC
Nominal Discharge Current In 20kA 20kA 20kA 20kA
Max Discharge Current lmax 40kA 40 kA 40kA 40kA
Protection level Up 2.8kV 3.0kV 3.5kV 5.5 kV
Rated shortcircuit current IscCI 100A
lcpv 0.2 mA
Connection mode paralle
Response Time tA 25ns
Back up fuse LT-SSD40
Remotecommunication With
Remote communication connection 1411:NO,1112:NC
Remote contact rated current 220V/0.5A
Associateddisconnectors
Thermal disconnector internal
Fuses Fuses type gG100A
ground fault breaker None
Mechnicalcharacteristics
Connection By screw terminals:6-35mm
Terminal Screw Torque 2.5 Nm
RecommendedCable cross Section 16mm²
Insertwire length 15mm
Mounting DIN rail 35mm (EN60715)
Degree of Protection IP20
Housing PBT
Flame retardant grade UL94 V0
Operating temperature -40ºC~+70ºC
Operatingrelative humidity 5%-95%
Working atmospheric pressure 70kPa~106kPa
Connection By screw terminals:6-35mm
Installation Instructions

Selection of SPD:
When embarking on the selection journey of a Surge Protection Device (SPD) for your power distribution system, it's imperative to focus on pivotal characteristics that shape the lightning protection mechanism. This guarantees that the electrical framework within any structure is thoroughly shielded, offering peace of mind and sustained safety.

  • SPD
    • Quantity of SPD
    • Type
    • Evaluating the exposure level to pinpoint the SPD's maximum discharge current, famously referred to as Imax, is an absolute necessity in your selection process.
  • Short Circuit Protection Device
    • Maximum discharge current, or Imax;
    • Short-circuit current, or Isc, at the precise installation point.
Versatile DC Surge Protector 275V 255V, 20kA In, 40kA Imax

Other crucial characteristics necessary for the selection of an SPD are typically predefined, tailor-made for a specific electrical installation scenario.

  • Number of poles in SPD;
  • Voltage protection level, Up;
  • Operating voltage, Uc.

This sub-sectionDesign of the Electrical Installation Protection SystemThis section delves deeply into the meticulous criteria needed for selecting a protection system. It thoroughly considers the installation specifics, the equipment that requires safeguarding, and the environmental conditions.

Location and Types of SPD:
Versatile DC Surge Protector 275V 255V, 20kA In, 40kA Imax

Connection of SPD:
Ensure SPD connections to loads are kept remarkably short to minimize the voltage protection level (installed Up) at the terminals of the safeguarded equipment.

The comprehensive length of SPD connections to both the network and the earth terminal block should be meticulously kept under 50 cm.

Versatile DC Surge Protector 275V 255V, 20kA In, 40kA Imax
Versatile DC Surge Protector 275V 255V, 20kA In, 40kA Imax

SPD Enclosures: Available options are SPD housed in a plastic enclosure or encased within a metal enclosure.

Versatile DC Surge Protector 275V 255V, 20kA In, 40kA Imax
Versatile DC Surge Protector 275V 255V, 20kA In, 40kA Imax

 

RED: Replace
When the indicator turns RED, it is a clear signal that the product's limit has been reached. It must be replaced promptly to ensure ongoing protection and efficiency.
Versatile DC Surge Protector 275V 255V, 20kA In, 40kA Imax

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier