Customization: | Available |
---|---|
Type: | Power Source Arrester |
Structure: | Zinc Oxide Arrester |
Still deciding? Get samples of $ !
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Introducing Taimu Electrical's SPD Surge Protective Devices: the unrivaled protectors of your electronic sanctum, meticulously engineered to defend against the capricious onslaught of voltage surges. Imagine the formidable force of a lightning strike, unleashing a torrent of hundreds of thousands of volts, threatening to compromise your critical equipment. While such dramatic events account for a mere 20% of surges, the true menace lies within-the stealthy, internal surges constituting a massive 80%. Though less dramatic than a lightning strike, their relentless occurrence can subtly but surely degrade sensitive electronics within your premises.
Power surges, those ephemeral voltage overloads, pose a serious threat that can lead to the premature failure of your cherished electrical devices. The impact of these surges reverberates through an array of household staples, inevitably curtailing their longevity and efficiency:
NEW 2020 National Electrical Code Requirements
In accordance with the landmark 2020 National Electrical Code, every new and retrofitted home must be equipped with Listed and Approved Type 1 or Type 2 Surge Protective Devices, establishing an elevated benchmark of security.
Type 1:
A robust, permanently connected Surge Protective Device that serves as a formidable defender against both external and internal voltage surges. Its versatile installation allows it to be placed either within or outside your home, providing flexible protective options.
Type 2:
A vigorous, permanently connected Surge Protective Device, strategically installed near or within the breaker box to effectively combat both internal and external surges, ensuring comprehensive coverage.
Type 3:
Offering supreme protection, this point-of-use Surge Protective Device delivers an added shield when used alongside Type 1 or Type 2 SPDs, aligning perfectly with the 2020 code standards for optimal defense.
For the ultimate in electrical safety, deploy a strategic blend of Type 1, 2, and 3 Surge Protective Devices, ensuring your home stands impregnable against any electrical disturbances.
Max Continuous Operating Voltage | Ucpv | 500VDC | 600VDC | 1000VDC | 1500VDC | ||||||
Nominal Discharge Current | In | 20kA | 20kA | 20kA | 20kA | ||||||
Max Discharge Current | lmax | 40kA | 40 kA | 40kA | 40kA | ||||||
Protection level | Up | 2.8kV | 3.0kV | 3.5kV | 5.5 kV | ||||||
Rated shortcircuit current | IscCI | 100A | |||||||||
lcpv | 0.2 mA | ||||||||||
Connection mode | paralle | ||||||||||
Response Time | tA | 25ns | |||||||||
Back up fuse | LT-SSD40 | ||||||||||
Remotecommunication | With | ||||||||||
Remote communication connection | 1411:NO,1112:NC | ||||||||||
Remote contact rated current | 220V/0.5A | ||||||||||
Associateddisconnectors | |||||||||||
Thermal disconnector | internal | ||||||||||
Fuses | Fuses type gG100A | ||||||||||
ground fault breaker | None | ||||||||||
Mechnicalcharacteristics | |||||||||||
Connection | By screw terminals:6-35mm | ||||||||||
Terminal Screw Torque | 2.5 Nm | ||||||||||
RecommendedCable cross Section | ≥16mm² | ||||||||||
Insertwire length | 15mm | ||||||||||
Mounting | DIN rail 35mm (EN60715) | ||||||||||
Degree of Protection | IP20 | ||||||||||
Housing | PBT | ||||||||||
Flame retardant grade | UL94 V0 | ||||||||||
Operating temperature | -40ºC~+70ºC | ||||||||||
Operatingrelative humidity | 5%-95% | ||||||||||
Working atmospheric pressure | 70kPa~106kPa | ||||||||||
Connection | By screw terminals:6-35mm |
Selection of SPD:
When embarking on the selection journey of a Surge Protection Device (SPD) for your power distribution system, it's imperative to focus on pivotal characteristics that shape the lightning protection mechanism. This guarantees that the electrical framework within any structure is thoroughly shielded, offering peace of mind and sustained safety.
Other crucial characteristics necessary for the selection of an SPD are typically predefined, tailor-made for a specific electrical installation scenario.
This sub-sectionDesign of the Electrical Installation Protection SystemThis section delves deeply into the meticulous criteria needed for selecting a protection system. It thoroughly considers the installation specifics, the equipment that requires safeguarding, and the environmental conditions.
Location and Types of SPD:
Connection of SPD:
Ensure SPD connections to loads are kept remarkably short to minimize the voltage protection level (installed Up) at the terminals of the safeguarded equipment.
The comprehensive length of SPD connections to both the network and the earth terminal block should be meticulously kept under 50 cm.
SPD Enclosures: Available options are SPD housed in a plastic enclosure or encased within a metal enclosure.
RED: Replace