Customization: | Available |
---|---|
Type: | Power Source Arrester |
Structure: | Valve Type Arrester |
Still deciding? Get samples of $ !
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Discover the ultimate defense for your electrical systems with Taimu Electrical's Advanced 230V Surge Protector. Expertly crafted to combat transient surge conditions, our state-of-the-art device provides formidable protection against massive surge events, such as lightning strikes. Such events can unleash devastating voltages, risking immediate or gradual equipment failure. Interestingly, lightning and utility disturbances account for just 20% of surges, with a remarkable 80% originating internally. Though typically lower in magnitude, these internal surges are frequent and can gradually erode the performance and longevity of your vital electronic devices.
Product Features
1. Experience unparalleled safety with our versatile 1P+N phase protection, effective for both AC and DC systems.
2. Enjoy seamless installation and maintenance with our ingenious pluggable module design, tailored for user convenience.
3. Benefit from our product's extraordinary high discharge capacity and swift response time, delivering unmatched surge protection.
4. Enhanced safety is assured with double thermal disconnection devices, providing robust and dependable protection.
5. Stay informed with our innovative green window indicator that changes upon fault detection, along with remote alarm control for vigilant monitoring.
A power surge, a fleeting overvoltage occurrence, poses a dangerous threat to electronic devices, often resulting in unforeseen failures and decreased operational lifespan. These surges have the destructive potential to impair and significantly reduce the lifespan of an array of household systems and appliances, which include:
It's startling to note that the National Electrical Manufacturers Association reveals the average household harbors around $15,000 in equipment that could be susceptible to surge damage.
Common Causes of Surges:
Experts approximate that an astounding 80% of surges are generated by internal sources within the premises.
Internal Sources:
External Sources:
NEW 2020 National Electrical Code Requirements
The cutting-edge 2020 code mandates that all new and renovated homes must be fitted with Listed and Approved Type 1 or Type 2 Surge Protective Devices, ensuring peak safety and adherence to standards.
Type 1:
This permanently connected Surge Protective Device, Type 1, offers extensive protection from both external and internal surges, suitable for installation inside or outside the home.
Type 2:
This Surge Protective Device, permanently connected, fits within or near the breaker box, providing defense against both internal and external surges.
Type 3:
For comprehensive protection, the Type 3 is a point-of-use Surge Protective Device, to be used along with Type 1 or Type 2 SPDs as per 2020 code requirements, ensuring optimal protection.
For the ultimate in protection, leveraging Type 1, 2, and 3 SPDs together is recommended, offering the highest level of surge defense.
Product category | Surge protection | |
Product type | SURGE PROTECTIVE DEVICE | |
Product model | HLSPD,SPD,TMSPD2 | |
Unique selling proposition | ·TMSPD1 SPD are suit for IT,TT,TN-C,TN-S,TN-C-S and low-voltage AC power distribution system, protect both direct and indirect lighting impulse and other transient over voltage. ·TMSPD1 surge protection device have high energy MOV chip, fast response speed. ·Products comply with IEC61643-1.2005, IEC61643-11.2011 standard. |
|
Technical data | Type of SPD according to EN 61643-11 | Type 2 |
SPD according to IEC 61643-1 | Class II | |
Nominal a.c voltage( Un) | 230V | |
Max continuous operating a.c voltage (Uc) | 275/320/385/440V | |
Nominal discharge current (In 8/20|jS) | 10/20KA | |
Max. discharge current (Imax 8/20pS) | 20/40KA | |
Voltage protection level (Up) | <1.3/1.4/1.5/1.8/2.2KV | |
Response time (tA) | <25ns | |
Operating temperature range (Tu) | -40°C +80°C | |
Operating state/fault indication | Green/red | |
Cross-section area (min) | 4mm² | |
Cross-section area (Max) | 16mm² | |
For mounting on | 35mm DIN rail acc to EN60715 | |
Degree of protection | IP20 | |
Terminal screw torque | 2.5N·m | |
Approvals | TUV |
Selection of SPD: A Key to Robust Electrical Safety
For an optimal power distribution system, the fundamental features that meticulously define a lightning protection strategy, and the precise selection of a suitable Surge Protective Device (SPD) to effectively safeguard an electrical installation within a building, include the following essential elements:
Additional characteristics for selecting a SPD are meticulously predefined for ensuring seamless integration within an electrical installation.
This Sub-section: A Detailed InsightDesign of the Electrical Installation Protection System: Unveiling the Blueprint for SafetyThis segment delves into an in-depth exploration of the criteria for selecting the protection system. It is based on key installation characteristics, the equipment requiring protection, and the unique surrounding environment.
Location and Types of SPD: Strategically Positioned for Precision
Connection of SPD: Ensuring Seamless Energy Flow
Ensure SPD connections to the loads are minimized in length. This effectively lowers the voltage protection level (installed Up) at the terminals of the protected devices, enhancing their safety.
The cumulative length of SPD connections to both the network and the earth terminal block must be kept within a stringent limit of 50 cm, optimizing performance.
SPD in a Plastic Enclosure versus SPD in a Metal Enclosure: Tailored to Your Needs
RED: Immediate Replacement Required