1P+N Afdd Circuit Breaker, IEC 61009-1, B/C/D Tripping Curve

Product Details
Customization: Available
Breaking Capacity: Low Voltage Circuit Breakers
Operation: Electric Type
Still deciding? Get samples of $ !
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company

360° Virtual Tour

Industry-leading Audited Factory

Secured Trading Service
Diamond Member Since 2015

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
to see all verified strength labels (22)
  • 1P+N Afdd Circuit Breaker, IEC 61009-1, B/C/D Tripping Curve
  • 1P+N Afdd Circuit Breaker, IEC 61009-1, B/C/D Tripping Curve
  • 1P+N Afdd Circuit Breaker, IEC 61009-1, B/C/D Tripping Curve
  • 1P+N Afdd Circuit Breaker, IEC 61009-1, B/C/D Tripping Curve
  • 1P+N Afdd Circuit Breaker, IEC 61009-1, B/C/D Tripping Curve
  • 1P+N Afdd Circuit Breaker, IEC 61009-1, B/C/D Tripping Curve
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • FAQ
  • Our Advantages
  • Certifications
  • Packaging & Shipping
  • Installation Instructions
  • Company Profile
Overview

Basic Info.

Model NO.
TMA3-40 6kA C25 TypeAC 1p+N
Speed
High-Speed Circuit Breaker
Arc-extinguishing Medium
Air
Installation
Fixed
Structure
AFDD
Poles Number
1P+N
Type
Circuit Breaker
Function
Overcurrent Protection, RCCB
Certification
VDE, ISO9001-2000, CE, CB, Ukca, NF
Standard
IEC/En 62606 & IEC 61009-1
Pole
1P+N
Tripping Curve
B, C, D
Rated Current (in)
6A, 10A, 16A, 20A, 25A, 32A, 40A
Residual Current Type
Type A, AC
Residual Current (LΔn)
30mA, 100mA, 300mA
Making Breaking Capacity (IΔm)
2, 000A
Icn
6kA
Energy Limiting Class
3
keywords
afdd and rcd
keywords2
afdd circuit breaker
keywords3
arc detection device
Transport Package
White Gift Box, Yellow Carton Box
Specification
115 x 69.6 x 18 mm
Trademark
Timelec, OEM / Private Label brands
Origin
China
HS Code
8536200000
Production Capacity
200, 000

Packaging & Delivery

Package Size
9.00cm * 3.30cm * 13.00cm
Package Gross Weight
0.200kg

Product Description

Product Description

The AFDD, also known as the Arc-Fault Detection Device or AFCI (Arc Fault Circuit Interrupter) in North America, is meticulously designed to comply with the rigorous standards of IEC/BS EN 62606.
When it comes to circuit protection, Timelec offers an unparalleled range of solutions. Our MCB provides robust short-circuit and overload protection, while the RCD (RCCB) ensures reliable residual current protection. However, for comprehensive safety, AFDD is indispensable as it addresses arc protection, crucial since statistics reveal that 90% of electrical fires originate from electric arcs.

 

The Timelec AFDD combines the capabilities of AFDD+RCBO, delivering an all-encompassing defense against short-circuits, overloads, residual currents, electrical arcs, and over-voltage conditions. Compliant with IEC/BS EN 62606 and IEC/BS EN 61009-1 standards, it proficiently discerns harmless arcs from those that pose potential danger. For instance, it interrupts the circuit upon detecting an electric arc, a common indicator of loose connections in home wiring, which may progressively lead to hazardous conditions like house fires.

Product Parameters
Product category CIRCUIT BREAKER
Product type ARC FAULT DETECTION DEVICES (AFDDs)
Product model TMA3-40
Unique selling
proposition
With AFD+RCBO protection
With Over-vol. protection
Total length, 115mm
Technical data   Standard IEC/EN 62606 & IEC 61009-1
Electrical features Rated curret (In) 6A,10A,16A,20A,25A,32A,40A
Trip curve B, C, D
Model Electronic
RCD Type AC, A
Pole 1P+N
Rate voltage (Ue) 240V
Insulation voltage(Ui) 500V
Rated frequency 50Hz
Energy limiting class 3
Rated residual operating current (IΔn) 30mA, 100mA, 300mA
Rated breaking capacity (Icn) 6KA
Rated operating short circuit breaking capacity (Ics) 6KA
Rated residual making and breaking capacity(IΔm) 2000A
Rated impulse withstand voltage (Uimp) 4KV
Surge current resistance / at (8/20) μs 3KA
Overvoltage protection 270V-300V
Electrical life 4,000
Pollution degree 2
Mechanical features Mechanical life 20,000
Protection degree IP20
Ambient temperature (with daily averages35°C) -25°C +40°C
Storage temperature -25°C +70°C
Installation Terminal connection type Cable, busbar
Connection capacity (input) 25mm2
Connection capacity (output) 16mm2
Tightening torque (input) 2.5Nm
Tightening torque (output) 1.2Nm
35mm DIN rail
1P+N Afdd Circuit Breaker, IEC 61009-1, B/C/D Tripping Curve
FAQ
Whatarearcs?
Visible plasma discharges caused by electrical current passing through a normally nonconductive medium, such as air.
It is caused when the electrical current ionizes gases in the air.
The temperature can exceed 600 ºC, sufficient to start a fire.
(20% fire associated with electrical distribution or other electrical appliance faults.)
1P+N Afdd Circuit Breaker, IEC 61009-1, B/C/D Tripping Curve
Whatcauses arcs?
An arc is created when the electrical current jumps between two conductive material. Most 2 types of arcs are Serial
Arc and Parallel Arc.

Most common causes includes:
1. worn contacts in electrical equipment,
2. damage to insulation,
3. break in cable and loose connections, Etc.
1P+N Afdd Circuit Breaker, IEC 61009-1, B/C/D Tripping Curve


What is AFDD?
AFDD is protective device installed in consumer units to provide protection from arc faults.
It uses microprocessor technology to analyze the waveform of the electricity being used to detect any unusual signatures
which would signify an arc on the circuit.

It will cut off the power to the affected circuit and could prevent a fire.
1P+N Afdd Circuit Breaker, IEC 61009-1, B/C/D Tripping Curve
Do I need to install AFDD?
Yes, it is highly recommended where there is an increased risk of fire
1P+N Afdd Circuit Breaker, IEC 61009-1, B/C/D Tripping Curve1P+N Afdd Circuit Breaker, IEC 61009-1, B/C/D Tripping Curve
According to IEC 60364 - Electrical installations of buildings Part 4-42 :
Arc Fault Detection Devices are designed to limit fire risks caused by the presence of arc fault currents in the final circuits of a fixed installation.They are installed in electrical switchboards, to protect circuits supplying power sockets and lighting and are especially recommended in cases of renovation.


More specifically, the installation of the AFDD is highly recommended to protect circuits with highest risk of fire, such as:
Protruding cables (risk of knocks)
Outside cables (greater risk of deterioration)
Unprotected cables in secluded areas (like storage rooms)
Aging, deteriorating wiring or wiring for which the connection boxes are inaccessible.
Our Advantages

The Timelec AFDD (AFCI) is designed with a total length of 115mm, offering a compact form without sacrificing performance.
Its compact design makes no compromise on functionality, delivering superior protection in a space-efficient form.

Choose Timelec for the ultimate in protection and prevention, ideal for both domestic and commercial applications.

Timelec offers exceptional customization options:

Print options include laser printing or pad printing to suit your needs;
Packaging choices range from an elegant white gift box for selected product types, enhancing perceived value,
to a practical yellow carton box that serves as a bulk packaging solution for the entire range.
Product design customization is available, with new molds created based on volume requirements.
 
Certifications
1P+N Afdd Circuit Breaker, IEC 61009-1, B/C/D Tripping Curve
1P+N Afdd Circuit Breaker, IEC 61009-1, B/C/D Tripping Curve
1P+N Afdd Circuit Breaker, IEC 61009-1, B/C/D Tripping Curve
1P+N Afdd Circuit Breaker, IEC 61009-1, B/C/D Tripping Curve
1P+N Afdd Circuit Breaker, IEC 61009-1, B/C/D Tripping Curve
1P+N Afdd Circuit Breaker, IEC 61009-1, B/C/D Tripping Curve

 

Packaging & Shipping

Each product can be presented in a white gift box, with 1 piece per box, ideal for gift sets.

1P+N Afdd Circuit Breaker, IEC 61009-1, B/C/D Tripping Curve
1P+N Afdd Circuit Breaker, IEC 61009-1, B/C/D Tripping Curve
1P+N Afdd Circuit Breaker, IEC 61009-1, B/C/D Tripping Curve


The yellow carton box can accommodate 60 pieces per carton, perfect for larger distribution needs.

1P+N Afdd Circuit Breaker, IEC 61009-1, B/C/D Tripping Curve
As a key component in the distribution channel,
Timelec offers corrugated carton boxes featuring:

High-quality material for durability,
Exceptional edge crush resistance for reliable protection,
and sleek, neutral black print for a professional appearance.

 

Installation Instructions

1P+N Afdd Circuit Breaker, IEC 61009-1, B/C/D Tripping Curve

Company Profile

1P+N Afdd Circuit Breaker, IEC 61009-1, B/C/D Tripping Curve1P+N Afdd Circuit Breaker, IEC 61009-1, B/C/D Tripping Curve1P+N Afdd Circuit Breaker, IEC 61009-1, B/C/D Tripping Curve1P+N Afdd Circuit Breaker, IEC 61009-1, B/C/D Tripping Curve

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier