Reliable DC Surge Protection Device (SPD) - Type 2, 40kA Direct Current Surge Protector

Contact Supplier

Product Images of Reliable DC Surge Protection Device (SPD) - Type 2, 40kA Direct Current Surge Protector

Reliable DC Surge Protection Device (SPD) - Type 2, 40kA Direct Current Surge Protector
Reliable DC Surge Protection Device (SPD) - Type 2, 40kA Direct Current Surge Protector pictures & photos
Reliable DC Surge Protection Device (SPD) - Type 2, 40kA Direct Current Surge Protector
  • Reliable DC Surge Protection Device (SPD) - Type 2, 40kA Direct Current Surge Protector
  • Reliable DC Surge Protection Device (SPD) - Type 2, 40kA Direct Current Surge Protector
    Reliable DC Surge Protection Device (SPD) - Type 2, 40kA Direct Current Surge Protector

Find Similar Products

Product Description

Product Description

SPD Surge Protective Devices are designed to protect against transient surge conditions. Large single surge events, such as lightning, can reach hundreds of thousands of volts and can cause immediate or intermittent equipment failure. However, lightning and utility power anomalies only account for 20% of transient surges. The remaining 80% of surge activity is produced internally. Although these surges may be smaller in magnitude, they occur more frequently and with continuous exposure can degrade sensitive electronic equipment within the facility.


A power surge is a brief overvoltage event that can damage electrical devices and is a common cause for the failure of electrical equipment. Surges can damage and reduce the lifespan of:

  • Heating and Air Conditioning Systems
  • Washers and Dryers
  • Water Heaters
  • Ranges & Refrigerators
  • Lighting
  • Entertainment Systems

NEW 2020 National Electrical Code Requirements
All new and renovated homes are required to be protected by Listed and Approved Type 1 or Type 2 Surge Protective Devices.

Type 1:
Permanently connected Surge Protective Device.  Protects against external and internal surges. May be installed inside or outside the home.

Type 2:
Permanently connected Surge Protective Device installed in, or next to, breaker box. Protects again internal or external surges.

Type 3:
Extra protection. Point-of-use Surge Protective Device. Must be used in conjunction with Type 1 or Type 2 SPD to meet 2020 code requirements.

Use Type 1, 2, and 3 SPDs for the best level of protection.  
 

Product Parameters
Max Continuous Operating Voltage Ucpv 500VDC 600VDC 1000VDC 1500VDC
Nominal Discharge Current In 20kA 20kA 20kA 20kA
Max Discharge Current lmax 40kA 40 kA 40kA 40kA
Protection level Up 2.8kV 3.0kV 3.5kV 5.5 kV
Rated shortcircuit current IscCI 100A
lcpv 0.2 mA
Connection mode paralle
Response Time tA 25ns
Back up fuse LT-SSD40
Remotecommunication With
Remote communication connection 1411:NO,1112:NC
Remote contact rated current 220V/0.5A
Associated disconnectors
Thermal disconnector internal
Fuses Fuses type gG100A
ground fault breaker None
Mechnical characteristics
Connection By screw terminals:6-35mm
Terminal Screw Torque 2.5 Nm
RecommendedCable cross Section 16mm²
Insertwire length 15mm
Mounting DIN rail 35mm (EN60715)
Degree of Protection IP20
Housing PBT
Flame retardant grade UL94 V0
Operating temperature -40ºC~+70ºC
Operatingrelative humidity 5%-95%
Working atmospheric pressure 70kPa~106kPa
Connection By screw terminals:6-35mm
Installation Instructions

Selection of SPD:
For a power distribution system, the main characteristics used to define the lightning protection system and select a SPD to protect an electrical installation in a building are:

  • SPD
    • quantity of SPD
    • type
    • level of exposure to define the SPD's maximum discharge current Imax.
  • Short circuit protection device
    • maximum discharge current Imax;
    • short-circuit current Isc at the point of installation.
Reliable DC Surge Protection Device (SPD) - Type 2, 40kA Direct Current Surge Protector

The other characteristics for selection of a SPD are predefined for an electrical installation.

  • number of poles in SPD;
  • voltage protection level Up;
  • operating voltage Uc.

This sub-section Design of the electrical installation protection system describes in greater detail the criteria for selection of the protection system according to the characteristics of the installation, the equipment to be protected and the environment.

Location and types of SPD:
Reliable DC Surge Protection Device (SPD) - Type 2, 40kA Direct Current Surge Protector

Connection of SPD:
Connections of a SPD to the loads should be as short as possible in order to reduce the value of the voltage protection level (installed Up) on the terminals of the protected equipment.

The total length of SPD connections to the network and the earth terminal block should not exceed 50 cm.

Reliable DC Surge Protection Device (SPD) - Type 2, 40kA Direct Current Surge Protector
Reliable DC Surge Protection Device (SPD) - Type 2, 40kA Direct Current Surge Protector

                                    SPD in plastic enclosure                                                                             SPD in metal enclosure
 

Reliable DC Surge Protection Device (SPD) - Type 2, 40kA Direct Current Surge Protector
Reliable DC Surge Protection Device (SPD) - Type 2, 40kA Direct Current Surge Protector

 

RED: Replace
Once the indicator shows RED, the product must be replaced.
Reliable DC Surge Protection Device (SPD) - Type 2, 40kA Direct Current Surge Protector

About the Supplier

This supplier has been audited by SGS. Verify the report on the official SGS website with ID "QIP-ASR253171". Items marked "verified" are certified.

Watch Video
Watch Video
Taimu Electrical (Hangzhou)Co., Ltd.
Taimu Electrical (Hangzhou)Co., Ltd.
Taimu Electrical (Hangzhou)Co., Ltd.
Taimu Electrical (Hangzhou)Co., Ltd.
Taimu Electrical (Hangzhou)Co., Ltd.
Taimu Electrical (Hangzhou)Co., Ltd.
Taimu Electrical (Hangzhou)Co., Ltd.
Taimu Electrical (Hangzhou)Co., Ltd.

About Our Factory & Business Background

verified Business Type
Manufacturer/Factory & Trading Company
Address
Floor.4, Building.8, Longchuanwu Road.157, 311100 Hangzhou, China
verified Plant Area
14604 square meters
verified Number of Employees
316
verified Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment
verified International Commercial Terms(Incoterms)
FOB, CIF, CFR, EXW
verified Average Lead Time
Peak Season Lead Time: one month
Off Season Lead Time: one month
verified Nearest Port
Shanghai Port, Ningbo Port
verified Minimum Order Quantity
12 pcs
verified Supply Chain Partners
125

Our Production Capability & Technical Expertise

Main Products
MCB, SPD, RCCB, RCBO, Afdd, Isolator, MCCB, Distribution Box, Waterproof Distribution Box, Metal Box
verified Production Lines
43
verified Production Machines
Fully Automated Production Line, Assembly Line, Spot Welding, Verification Room, Testing Room, Lab, Aging Test Bench, Arc test bench
verified QA/QC inspectors
20 people
verified Inspection Type for Finished Products
100% inspection(Visual inspection & Function inspection)
verified Inspection Method for Finished Products
Have instructions and uniformly followed
verified Customization Options
Customization from Samples, Customization from Designs, Full Customization, Minor Customization, Flexible customization
verified ODM Service Available
Yes
verified OEM Service Available
Yes
verified R&D Engineers
26 people
verified Traceability of Raw Materials
No

Our Industry Experience & Global Business Record

verified Year of Establishment
2014-09-18
verified Export Year
10 years
verified Main Markets
Europe
verified Repeat Buyers Choice
50%~80%
verified Number of Foreign Trading Staff
4
verified Overseas Agent/Branch
No
verified New Products Launched in Last year
No

Our Certifications, Standards & Industry Recognition

verified Management System Certification
ISO9001:2015, ISO14001, ISO45001:2018, Others
verified Cooperated with Fortune 500
No

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now