Reliable DC Surge Protection Device (SPD) - Type 2, 40kA Direct Current Surge Protector
Contact Supplier
Product Attributes
- Type
- Power Source Arrester
- Structure
- Zinc Oxide Arrester
- Installation
- Tandem Arrester
- Model NO.
- TMSPD7
- Application
- AC/DC System
- Size
- Small
- Operation Voltage
- Low Voltage
- Shape
- Cuboid
- Material
- PBT Fireproof
- Certification
- ROHS, ISO9001, CE
- Brand
- Timelec
- Uc
- 275V / 255V
- In
- 20kA
- Imax
- 40kA
- Up
- 1.5kV
- IEC
- IEC61643-11
- IP
- IP20
- Protection
- Class II, T2
- Transport Package
- Carton Box
- Specification
- 18mm
- Trademark
- Timelec, OEM / Private Label brands
- Origin
- China
- HS Code
- 853620
- Production Capacity
- 1000000
- Package Size
- 22.70cm * 8.10cm * 9.00cm
- Package Gross Weight
- 1.300kg
Product Images of Reliable DC Surge Protection Device (SPD) - Type 2, 40kA Direct Current Surge Protector
Find Similar Products
Product Description
SPD Surge Protective Devices are designed to protect against transient surge conditions. Large single surge events, such as lightning, can reach hundreds of thousands of volts and can cause immediate or intermittent equipment failure. However, lightning and utility power anomalies only account for 20% of transient surges. The remaining 80% of surge activity is produced internally. Although these surges may be smaller in magnitude, they occur more frequently and with continuous exposure can degrade sensitive electronic equipment within the facility.
A power surge is a brief overvoltage event that can damage electrical devices and is a common cause for the failure of electrical equipment. Surges can damage and reduce the lifespan of:
- Heating and Air Conditioning Systems
- Washers and Dryers
- Water Heaters
- Ranges & Refrigerators
- Lighting
- Entertainment Systems
NEW 2020 National Electrical Code Requirements
All new and renovated homes are required to be protected by Listed and Approved Type 1 or Type 2 Surge Protective Devices.
Type 1:
Permanently connected Surge Protective Device. Protects against external and internal surges. May be installed inside or outside the home.
Type 2:
Permanently connected Surge Protective Device installed in, or next to, breaker box. Protects again internal or external surges.
Type 3:
Extra protection. Point-of-use Surge Protective Device. Must be used in conjunction with Type 1 or Type 2 SPD to meet 2020 code requirements.
Use Type 1, 2, and 3 SPDs for the best level of protection.
| Max Continuous Operating Voltage | Ucpv | 500VDC | 600VDC | 1000VDC | 1500VDC | ||||||
| Nominal Discharge Current | In | 20kA | 20kA | 20kA | 20kA | ||||||
| Max Discharge Current | lmax | 40kA | 40 kA | 40kA | 40kA | ||||||
| Protection level | Up | 2.8kV | 3.0kV | 3.5kV | 5.5 kV | ||||||
| Rated shortcircuit current | IscCI | 100A | |||||||||
| lcpv | 0.2 mA | ||||||||||
| Connection mode | paralle | ||||||||||
| Response Time | tA | 25ns | |||||||||
| Back up fuse | LT-SSD40 | ||||||||||
| Remotecommunication | With | ||||||||||
| Remote communication connection | 1411:NO,1112:NC | ||||||||||
| Remote contact rated current | 220V/0.5A | ||||||||||
| Associated disconnectors | |||||||||||
| Thermal disconnector | internal | ||||||||||
| Fuses | Fuses type gG100A | ||||||||||
| ground fault breaker | None | ||||||||||
| Mechnical characteristics | |||||||||||
| Connection | By screw terminals:6-35mm | ||||||||||
| Terminal Screw Torque | 2.5 Nm | ||||||||||
| RecommendedCable cross Section | ≥16mm² | ||||||||||
| Insertwire length | 15mm | ||||||||||
| Mounting | DIN rail 35mm (EN60715) | ||||||||||
| Degree of Protection | IP20 | ||||||||||
| Housing | PBT | ||||||||||
| Flame retardant grade | UL94 V0 | ||||||||||
| Operating temperature | -40ºC~+70ºC | ||||||||||
| Operatingrelative humidity | 5%-95% | ||||||||||
| Working atmospheric pressure | 70kPa~106kPa | ||||||||||
| Connection | By screw terminals:6-35mm | ||||||||||
Selection of SPD:
For a power distribution system, the main characteristics used to define the lightning protection system and select a SPD to protect an electrical installation in a building are:
- SPD
- quantity of SPD
- type
- level of exposure to define the SPD's maximum discharge current Imax.
- Short circuit protection device
- maximum discharge current Imax;
- short-circuit current Isc at the point of installation.
The other characteristics for selection of a SPD are predefined for an electrical installation.
- number of poles in SPD;
- voltage protection level Up;
- operating voltage Uc.
This sub-section Design of the electrical installation protection system describes in greater detail the criteria for selection of the protection system according to the characteristics of the installation, the equipment to be protected and the environment.
Location and types of SPD:
Connection of SPD:
Connections of a SPD to the loads should be as short as possible in order to reduce the value of the voltage protection level (installed Up) on the terminals of the protected equipment.
The total length of SPD connections to the network and the earth terminal block should not exceed 50 cm.
SPD in plastic enclosure SPD in metal enclosure
RED: Replace
Once the indicator shows RED, the product must be replaced.
About the Supplier
This supplier has been audited by SGS. Verify the report on the official SGS website with ID "QIP-ASR253171". Items marked "" are certified.
Company Profile
Established on 18 Sep 2014, Taimu Electrical (Hangzhou )Co., Ltd. is located in the beautiful city of Hangzhou. We are a national high-tech company with more than 500 associates, specialized in the design, manufacturing of low-voltage electrical safety devices. We obtained more than 50 domestic and international patents, more than a dozen government honors, which translates into more than USD 60 mio. Output to our partners worldwide.
Being accredited with ISO 9001: 2015 Quality Management System, ISO 14001: 2015 Environmental Management System, and ISO 45001: 2018 Occupational Health and Safety Management System, and fully certified with SEMKO, NF, CE, CB, UKCA, TUV, we manufacture high quality MCB, RCD (RCCB), RCBO (GFCI), AFDD (AFCI), Isolator switch, Auxiliary switch, distribution box, consumer units, SPD and more in low-voltage circuit protection applications.
Taking advantage of our exprienced management team using Lean Six Sigma production management system, we established long-term cooperation with Fortune 500 listed companies in low-voltage electrical components application, and our testing method is advanced and reliable, with support from Xi'an Jiaotong University.
We are committed to provide our customers with reliable, high price/quality ratio, customizable electrical products and professional services.
Our objective:
Become the world's most competitive supplier in low-voltage safety applications.
Our Mission Statement:
Intelligent control makes life more intelligent.
Our Slogan:
Your trusted partner for electrical safety products.
Our strategical focal points:
Focus on customers
We understand our customer's requirements. We tailor our products to them, and we create innovative solutions, or even business models.
Shaping change
We shape changes and seize the opportunities it brings, especially in emerging markets.
Striving for excellence
We measure ourselves against our strongest competitors. Our work is fast, agile and accurate. Efficient processes, lean structures and increase the value of the company.
About Our Factory & Business Background
-
Business Type
- Manufacturer/Factory & Trading Company
- Address
- Floor.4, Building.8, Longchuanwu Road.157, 311100 Hangzhou, China
-
Plant Area
- 14604 square meters
-
Number of Employees
- 316
-
Terms of Payment
- LC, T/T, D/P, PayPal, Western Union, Small-amount payment
-
International Commercial Terms(Incoterms)
- FOB, CIF, CFR, EXW
-
Average Lead Time
-
Peak Season Lead Time: one month
Off Season Lead Time: one month -
Nearest Port
- Shanghai Port, Ningbo Port
-
Minimum Order Quantity
- 12 pcs
-
Supply Chain Partners
- 125
Our Production Capability & Technical Expertise
- Main Products
- MCB, SPD, RCCB, RCBO, Afdd, Isolator, MCCB, Distribution Box, Waterproof Distribution Box, Metal Box
-
Production Lines
- 43
-
Production Machines
- Fully Automated Production Line, Assembly Line, Spot Welding, Verification Room, Testing Room, Lab, Aging Test Bench, Arc test bench
-
QA/QC inspectors
- 20 people
-
Inspection Type for Finished Products
- 100% inspection(Visual inspection & Function inspection)
-
Inspection Method for Finished Products
- Have instructions and uniformly followed
-
Customization Options
- Customization from Samples, Customization from Designs, Full Customization, Minor Customization, Flexible customization
-
ODM Service Available
- Yes
-
OEM Service Available
- Yes
-
R&D Engineers
- 26 people
-
Traceability of Raw Materials
- No
Our Industry Experience & Global Business Record
-
Year of Establishment
- 2014-09-18
-
Export Year
- 10 years
-
Main Markets
- Europe
-
Repeat Buyers Choice
- 50%~80%
-
Number of Foreign Trading Staff
- 4
-
Overseas Agent/Branch
- No
-
New Products Launched in Last year
- No
Our Certifications, Standards & Industry Recognition
-
Management System Certification
- ISO9001:2015, ISO14001, ISO45001:2018, Others
-
Cooperated with Fortune 500
- No
Send your message to this supplier
People who viewed this also viewed
-
US$2.16-2.22 / Piece
-
US$2.16-2.22 / Piece
-
US$2.16-2.22 / Piece
-
US$2.16-2.22 / Piece
-
US$4.12-4.32 / Piece
-
US$2.16-2.22 / Piece
-
US$4.12-4.32 / Piece
-
US$4.12-4.32 / Piece
-
US$2.16-2.22 / Piece
-
US$6.91-7.00 / Piece
Find Similar Products By Category
- Supplier Homepage
- Products
- Arrester
- Reliable DC Surge Protection Device (SPD) - Type 2, 40kA Direct Current Surge Protector
Related Categories
Hot Searches
- Electric Protector Factories
- Electrical Protector Factories
- Power Protector Factories
- Plastic Protector Factories
- N Surge Protector
- Surge Voltage Protector
- Surge Power Protector
- Protection Surge Protector
- Ac Surge Protector
- surge protector Bulkbuy