Afdd Circuit Breaker, 1P+N Configuration, IEC/EN 62606 Compliance

Product Details
Customization: Available
Breaking Capacity: Low Voltage Circuit Breakers
Operation: Electric Type
Still deciding? Get samples of $ !
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company

360° Virtual Tour

Industry-leading Audited Factory

Secured Trading Service
Diamond Member Since 2015

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
to see all verified strength labels (22)
  • Afdd Circuit Breaker, 1P+N Configuration, IEC/EN 62606 Compliance
  • Afdd Circuit Breaker, 1P+N Configuration, IEC/EN 62606 Compliance
  • Afdd Circuit Breaker, 1P+N Configuration, IEC/EN 62606 Compliance
  • Afdd Circuit Breaker, 1P+N Configuration, IEC/EN 62606 Compliance
  • Afdd Circuit Breaker, 1P+N Configuration, IEC/EN 62606 Compliance
  • Afdd Circuit Breaker, 1P+N Configuration, IEC/EN 62606 Compliance
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • FAQ
  • Our Advantages
  • Certifications
  • Packaging & Shipping
  • Installation Instructions
  • Company Profile
Overview

Basic Info.

Model NO.
TMA3-40 6kA C25 TypeAC 1p+N
Speed
High-Speed Circuit Breaker
Arc-extinguishing Medium
Air
Installation
Fixed
Structure
AFDD
Poles Number
1P+N
Type
Circuit Breaker
Function
Overcurrent Protection, RCCB
Certification
VDE, ISO9001-2000, CE, CB, Ukca, NF
Standard
IEC/En 62606 & IEC 61009-1
Pole
1P+N
Tripping Curve
B, C, D
Rated Current (in)
6A, 10A, 16A, 20A, 25A, 32A, 40A
Residual Current Type
Type A, AC
Residual Current (LΔn)
30mA, 100mA, 300mA
Making Breaking Capacity (IΔm)
2, 000A
Icn
6kA
Energy Limiting Class
3
keywords
afdd and rcd
keywords2
afdd circuit breaker
keywords3
arc detection device
Transport Package
White Gift Box, Yellow Carton Box
Specification
115 x 69.6 x 18 mm
Trademark
Timelec, OEM / Private Label brands
Origin
China
HS Code
8536200000
Production Capacity
200, 000

Packaging & Delivery

Package Size
9.00cm * 3.30cm * 13.00cm
Package Gross Weight
0.200kg

Product Description

Product Description

Introducing our revolutionary AFDD, the Arc-Fault Detection Device, also widely recognized as AFCI, the Arc Fault Circuit Interrupter in North America. Proudly adhering to the rigorous standards of IEC/BS EN 62606, this device stands as a beacon of electrical safety.
In the realm of circuit protection, Timelec leads with our MCB, expertly designed for short-circuit and overload protection, along with our RCD (RCCB) for safeguarding against residual currents. However, true electrical safety demands more. Astonishingly, 90% of fires are ignited by electric arcs. This underscores the essential need for our AFDD, which provides premier arc protection.

 

The Timelec AFDD is a sophisticated AFDD+RCBO system, offering an all-encompassing shield with short-circuit, overload, residual current, arc, and over-voltage protection. It meets the stringent standards of IEC/BS EN 62606 and IEC/BS EN 61009-1. This device is engineered to intelligently distinguish between harmless and potentially hazardous arcs. For instance, it disrupts the circuit upon detecting an electric arc, a common indicator of loose connections in home wiring, which could intensify over time and potentially lead to house fires.

Product Parameters
Product category CIRCUIT BREAKER
Product type ARC FAULT DETECTION DEVICES (AFDDs)
Product model TMA3-40
Unique selling
proposition
With AFD+RCBO protection
With Over-vol. protection
Total length, 115mm
Technical data   Standard IEC/EN 62606 & IEC 61009-1
Electrical features Rated curret (In) 6A,10A,16A,20A,25A,32A,40A
Trip curve B, C, D
Model Electronic
RCD Type AC, A
Pole 1P+N
Rate voltage (Ue) 240V
Insulation voltage(Ui) 500V
Rated frequency 50Hz
Energy limiting class 3
Rated residual operating current (IΔn) 30mA, 100mA, 300mA
Rated breaking capacity (Icn) 6KA
Rated operating short circuit breaking capacity (Ics) 6KA
Rated residual making and breaking capacity(IΔm) 2000A
Rated impulse withstand voltage (Uimp) 4KV
Surge current resistance / at (8/20) μs 3KA
Overvoltage protection 270V-300V
Electrical life 4,000
Pollution degree 2
Mechanical features Mechanical life 20,000
Protection degree IP20
Ambient temperature (with daily averages35°C) -25°C +40°C
Storage temperature -25°C +70°C
Installation Terminal connection type Cable, busbar
Connection capacity (input) 25mm2
Connection capacity (output) 16mm2
Tightening torque (input) 2.5Nm
Tightening torque (output) 1.2Nm
35mm DIN rail
Afdd Circuit Breaker, 1P+N Configuration, IEC/EN 62606 Compliance
FAQ
Whatarearcs?
Visible plasma discharges caused by electrical current passing through a normally nonconductive medium, such as air.
It is caused when the electrical current ionizes gases in the air.
The temperature can exceed 600 ºC, sufficient to start a fire.
(20% fire associated with electrical distribution or other electrical appliance faults.)
Afdd Circuit Breaker, 1P+N Configuration, IEC/EN 62606 Compliance
Whatcauses arcs?
An arc is created when the electrical current jumps between two conductive material. Most 2 types of arcs are Serial
Arc and Parallel Arc.

Most common causes includes:
1. worn contacts in electrical equipment,
2. damage to insulation,
3. break in cable and loose connections, Etc.
Afdd Circuit Breaker, 1P+N Configuration, IEC/EN 62606 Compliance


What is AFDD?
AFDD is protective device installed in consumer units to provide protection from arc faults.
It uses microprocessor technology to analyze the waveform of the electricity being used to detect any unusual signatures
which would signify an arc on the circuit.

It will cut off the power to the affected circuit and could prevent a fire.
Afdd Circuit Breaker, 1P+N Configuration, IEC/EN 62606 Compliance
Do I need to install AFDD?
Yes, it is highly recommended where there is an increased risk of fire
Afdd Circuit Breaker, 1P+N Configuration, IEC/EN 62606 ComplianceAfdd Circuit Breaker, 1P+N Configuration, IEC/EN 62606 Compliance
According to IEC 60364 - Electrical installations of buildings Part 4-42 :
Arc Fault Detection Devices are designed to limit fire risks caused by the presence of arc fault currents in the final circuits of a fixed installation.They are installed in electrical switchboards, to protect circuits supplying power sockets and lighting and are especially recommended in cases of renovation.


More specifically, the installation of the AFDD is highly recommended to protect circuits with highest risk of fire, such as:
Protruding cables (risk of knocks)
Outside cables (greater risk of deterioration)
Unprotected cables in secluded areas (like storage rooms)
Aging, deteriorating wiring or wiring for which the connection boxes are inaccessible.
Our Advantages

Timelec AFDD (AFCI) features a streamlined design with a total length of 115mm.
Compact without compromise, ensuring high performance and durability.

This is the ultimate choice for comprehensive protection and prevention, catering to both domestic and commercial application needs.

Timelec offers a variety of customization options:

Print options: laser / pad printing available;
Packaging options: elegant white gift box for selected product types, adding extra value;
economical yellow carton box for full range bulk packaging.
Product design: tailor-made based on volume to create new moulds.
 
Certifications
Afdd Circuit Breaker, 1P+N Configuration, IEC/EN 62606 Compliance
Afdd Circuit Breaker, 1P+N Configuration, IEC/EN 62606 Compliance
Afdd Circuit Breaker, 1P+N Configuration, IEC/EN 62606 Compliance
Afdd Circuit Breaker, 1P+N Configuration, IEC/EN 62606 Compliance
Afdd Circuit Breaker, 1P+N Configuration, IEC/EN 62606 Compliance
Afdd Circuit Breaker, 1P+N Configuration, IEC/EN 62606 Compliance

 

Packaging & Shipping

White gift box: accommodates 1 pc per gift box;

Afdd Circuit Breaker, 1P+N Configuration, IEC/EN 62606 Compliance
Afdd Circuit Breaker, 1P+N Configuration, IEC/EN 62606 Compliance
Afdd Circuit Breaker, 1P+N Configuration, IEC/EN 62606 Compliance


Yellow carton box: holds up to 60 pcs per carton box.

Afdd Circuit Breaker, 1P+N Configuration, IEC/EN 62606 Compliance
For distribution channels,
Timelec presents a robust corrugated carton box:

Crafted with high quality,
Engineered for high edge crush resistance,
Features neutral black print.

 

Installation Instructions

Afdd Circuit Breaker, 1P+N Configuration, IEC/EN 62606 Compliance

Company Profile

Afdd Circuit Breaker, 1P+N Configuration, IEC/EN 62606 ComplianceAfdd Circuit Breaker, 1P+N Configuration, IEC/EN 62606 ComplianceAfdd Circuit Breaker, 1P+N Configuration, IEC/EN 62606 ComplianceAfdd Circuit Breaker, 1P+N Configuration, IEC/EN 62606 Compliance

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier