Afdd Standard IEC/EN 62606 1P+N B/C/D Tripping Curve Circuit Breaker

Product Details
Customization: Available
Breaking Capacity: Low Voltage Circuit Breakers
Operation: Electric Type
Still deciding? Get samples of $ !
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW PayPal
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company

360° Virtual Tour

Industry-leading Audited Factory

Secured Trading Service
Diamond Member Since 2015

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
to see all verified strength labels (22)
  • Afdd Standard IEC/EN 62606 1P+N B/C/D Tripping Curve Circuit Breaker
  • Afdd Standard IEC/EN 62606 1P+N B/C/D Tripping Curve Circuit Breaker
  • Afdd Standard IEC/EN 62606 1P+N B/C/D Tripping Curve Circuit Breaker
  • Afdd Standard IEC/EN 62606 1P+N B/C/D Tripping Curve Circuit Breaker
  • Afdd Standard IEC/EN 62606 1P+N B/C/D Tripping Curve Circuit Breaker
  • Afdd Standard IEC/EN 62606 1P+N B/C/D Tripping Curve Circuit Breaker
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • FAQ
  • Our Advantages
  • Certifications
  • Packaging & Shipping
  • Installation Instructions
  • Company Profile
Overview

Basic Info.

Model NO.
TMA1-40 1P+N 6kA C40 TypeAC
Speed
High-Speed Circuit Breaker
Arc-extinguishing Medium
Air
Installation
Fixed
Structure
AFDD
Poles Number
1P+N
Type
Circuit Breaker
Function
Overcurrent Protection, RCCB
Certification
VDE, ISO9001-2000, CE, CB, Ukca, NF
Standard
IEC/En 62606 & IEC 61009-1
Pole
1P+N
Tripping Curve
B, C, D
Rated Current (in)
6A, 10A, 16A, 20A, 25A, 32A, 40A
Residual Current Type
Type A, AC
Residual Current (LΔn)
30mA, 100mA, 300mA
Making Breaking Capacity (IΔm)
2, 000A
Icn
6kA
Energy Limiting Class
3
keywords
afdd and rcd
keywords2
afdd circuit breaker
keywords3
arc detection device
Transport Package
White Gift Box, Yellow Carton Box
Specification
115 x 69.6 x 18 mm
Trademark
Timelec, OEM / Private Label brands
Origin
China
HS Code
8536200000
Production Capacity
200, 000

Packaging & Delivery

Package Size
9.00cm * 3.30cm * 1.20cm
Package Gross Weight
0.200kg

Product Description

Product Description

The AFDD, or Arc-Fault Detection Device, also recognized as AFCI (Arc Fault Circuit Interrupter in North America), represents the pinnacle of safety and reliability. It is meticulously crafted to meet the stringent requirements of IEC/BS EN 62606, ensuring that it delivers unmatched protection and peace of mind.
In the realm of circuit protection, Timelec establishes a benchmark with its extensive array of protective devices. Our MCBs are meticulously engineered to offer top-tier short-circuit and overload protection, while our RCDs (RCCB) deliver robust residual current safeguarding. Yet, traditional methods fall short. Astonishingly, 90% of electrical fires stem from electric arcs. Here, the AFDD is indispensable, providing crucial arc protection to shield lives and properties from potential hazards.

 

The Timelec AFDD is the ultimate all-in-one solution, seamlessly integrating AFDD and RCBO capabilities. It offers an expansive range of protection, including short-circuit, overload, residual current, arc, and over-voltage defense, all in strict compliance with IEC/BS EN 62606 and IEC/BS EN 61009-1 standards. Our innovative device astutely differentiates between benign and perilous arcs, automatically severing the circuit when detecting a potentially disastrous arc, often originating from loose connections in aging home wiring that could ignite dangerous fires.

Product Parameters
Product category CIRCUIT BREAKER
Product type ARC FAULT DETECTION DEVICES (AFDDs)
Product model TMA3-40
Unique selling
proposition
With AFD+RCBO protection
With Over-vol. protection
Total length, 115mm
Technical data   Standard IEC/EN 62606 & IEC 61009-1
Electrical features Rated curret (In) 6A,10A,16A,20A,25A,32A,40A
Trip curve B, C, D
Model Electronic
RCD Type AC, A
Pole 1P+N
Rate voltage (Ue) 240V
Insulation voltage(Ui) 500V
Rated frequency 50Hz
Energy limiting class 3
Rated residual operating current (IΔn) 30mA, 100mA, 300mA
Rated breaking capacity (Icn) 6KA
Rated operating short circuit breaking capacity (Ics) 6KA
Rated residual making and breaking capacity(IΔm) 2000A
Rated impulse withstand voltage (Uimp) 4KV
Surge current resistance / at (8/20) μs 3KA
Overvoltage protection 270V-300V
Electrical life 4,000
Pollution degree 2
Mechanical features Mechanical life 20,000
Protection degree IP20
Ambient temperature (with daily averages35°C) -25°C +40°C
Storage temperature -25°C +70°C
Installation Terminal connection type Cable, busbar
Connection capacity (input) 25mm2
Connection capacity (output) 16mm2
Tightening torque (input) 2.5Nm
Tightening torque (output) 1.2Nm
35mm DIN rail
Afdd Standard IEC/EN 62606 1P+N B/C/D Tripping Curve Circuit Breaker
FAQ
Whatarearcs?
Visible plasma discharges caused by electrical current passing through a normally nonconductive medium, such as air.
It is caused when the electrical current ionizes gases in the air.
The temperature can exceed 600 ºC, sufficient to start a fire.
(20% fire associated with electrical distribution or other electrical appliance faults.)
Afdd Standard IEC/EN 62606 1P+N B/C/D Tripping Curve Circuit Breaker
Whatcauses arcs?
An arc is created when the electrical current jumps between two conductive material. Most 2 types of arcs are Serial
Arc and Parallel Arc.

Most common causes includes:
1. worn contacts in electrical equipment,
2. damage to insulation,
3. break in cable and loose connections, Etc.
Afdd Standard IEC/EN 62606 1P+N B/C/D Tripping Curve Circuit Breaker


What is AFDD?
AFDD is protective device installed in consumer units to provide protection from arc faults.
It uses microprocessor technology to analyze the waveform of the electricity being used to detect any unusual signatures
which would signify an arc on the circuit.

It will cut off the power to the affected circuit and could prevent a fire.
Afdd Standard IEC/EN 62606 1P+N B/C/D Tripping Curve Circuit Breaker
Do I need to install AFDD?
Yes, it is highly recommended where there is an increased risk of fire
Afdd Standard IEC/EN 62606 1P+N B/C/D Tripping Curve Circuit BreakerAfdd Standard IEC/EN 62606 1P+N B/C/D Tripping Curve Circuit Breaker
According to IEC 60364 - Electrical installations of buildings Part 4-42 :
Arc Fault Detection Devices are designed to limit fire risks caused by the presence of arc fault currents in the final circuits of a fixed installation.They are installed in electrical switchboards, to protect circuits supplying power sockets and lighting and are especially recommended in cases of renovation.


More specifically, the installation of the AFDD is highly recommended to protect circuits with highest risk of fire, such as:
Protruding cables (risk of knocks)
Outside cables (greater risk of deterioration)
Unprotected cables in secluded areas (like storage rooms)
Aging, deteriorating wiring or wiring for which the connection boxes are inaccessible.
Our Advantages

The Timelec AFDD (AFCI) features an ingeniously compact design, measuring a mere 115mm in length, making it a versatile fit for any application.
Despite its sleek size, it delivers unwavering protection and performance, ensuring comprehensive safety without compromise.

For those seeking excellence in protection, the Timelec AFDD stands as the premier choice for both domestic and commercial spaces, offering unparalleled peace of mind and security.

Timelec offers an expansive array of customization options to suit your every need:

Choose from laser or pad printing for detailed and distinctive branding.
Select from elegant white gift boxes for certain products, elevating their perceived value and presentation.
For larger orders, robust yellow carton boxes are available for bulk packaging across the entire product range, ensuring durability and protection in transit.
Explore our innovative product design services, with new mold creation available to tailor your order by volume.
 
Certifications
Afdd Standard IEC/EN 62606 1P+N B/C/D Tripping Curve Circuit Breaker
Afdd Standard IEC/EN 62606 1P+N B/C/D Tripping Curve Circuit Breaker
Afdd Standard IEC/EN 62606 1P+N B/C/D Tripping Curve Circuit Breaker
Afdd Standard IEC/EN 62606 1P+N B/C/D Tripping Curve Circuit Breaker
Afdd Standard IEC/EN 62606 1P+N B/C/D Tripping Curve Circuit Breaker
Afdd Standard IEC/EN 62606 1P+N B/C/D Tripping Curve Circuit Breaker

 

Packaging & Shipping

Each product is carefully and elegantly encased in a white gift box, with 1 pc per box, ensuring a premium unboxing experience.

Afdd Standard IEC/EN 62606 1P+N B/C/D Tripping Curve Circuit Breaker
Afdd Standard IEC/EN 62606 1P+N B/C/D Tripping Curve Circuit Breaker
Afdd Standard IEC/EN 62606 1P+N B/C/D Tripping Curve Circuit Breaker


For larger orders, our efficient yellow carton boxes accommodate 60 pcs per carton, optimizing your storage and transportation needs.

Afdd Standard IEC/EN 62606 1P+N B/C/D Tripping Curve Circuit Breaker
Within our distribution network, we guarantee secure packaging with:
Timelec's durable corrugated carton boxes boast:

High-quality, resilient materials,
Outstanding edge crush resistance for maximum protection,
A neutral, sophisticated black print that adds a touch of class.

 

Installation Instructions

Afdd Standard IEC/EN 62606 1P+N B/C/D Tripping Curve Circuit Breaker

Company Profile

Afdd Standard IEC/EN 62606 1P+N B/C/D Tripping Curve Circuit BreakerAfdd Standard IEC/EN 62606 1P+N B/C/D Tripping Curve Circuit BreakerAfdd Standard IEC/EN 62606 1P+N B/C/D Tripping Curve Circuit BreakerAfdd Standard IEC/EN 62606 1P+N B/C/D Tripping Curve Circuit Breaker

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier